Maintenance Instructions; Maintenance Schedule; Checks Not Requiring Skilled Personnel; Checking The Engine Oil Level - Telair TIG 3000G Use And Maintenance Manual

Table of Contents

Advertisement

9 MAINTENANCE INSTRUCTIONS

9.1 Maintenance schedule

ROUTINE MAINTENANCE SCHEDULE
Performed to the achievement the condition that occurs first
Engine oil
Engine valves
Air filter
Ventilation ducts
Engine
vibration
damping
mounts
External
vibration
damping
mounts
Fuel pipes
(1) First replacement
Before performing any check or main-
tenance operation on the generating set, turn
the ON/OFF switch of the control panel to its
OFF position and the safety switch of the
control panel to its O position.
This way you can operate under safe condi-
tions as the generating set cannot start up.
If it is necessary to work on the electrical wir-
ing system or on one of the electronic
boards, remove the fuse provided on the di-
rect supply positive line to the generator or
disconnect the line from the battery.
Only use original spare parts. Using
poorer quality spare parts may damage your
generating set.
Periodic inspection and maintenance are es-
sential to preserve the generator performance
and ensure its long working life.
For more information on the mainte-
nance of the engine, please refer to the tech-
nical manual of the engine manufacturer,
supplied together with the generator.

9.2 Checks not requiring skilled personnel

To perform this kind of inspections, it will be nec-
essary to open the door of the generating set.
Vers. 001
GB
Level check
Replacement
Chek and adjustment
Chek (repalce if necessary)
Inspection and cleaning
Check (replace if necessary)
Check (replace if necessary)
Inspection
(replace
necessary)
TIG 3000 G
50 hours
100
or 4
hours or
months
one year
● (1)
if
The following precautions must therefore be
taken:
1) The generator must not be running.
2) All its parts must be cold.

9.2.1 Checking the engine oil level

Engine oil level checking must be car-
ried out with the engine stopped and with a
perfectly horizontal generating set.
Unscrew the engine oil cap (fig. 35 ref. 1), wipe
the dipstick clean if required, screw it back in its
seat and then unscrew it again to obtain an accu-
rate lubricant level reading. The dipstick must be
300
500
hours or
hours or
one year
one year
23

Advertisement

Table of Contents
loading

Table of Contents