Using Pass-Through Mode With Ddc Routed To A Local Monitor; Using Pass-Through Mode With Ddc Routed To The Remote Display - Extron electronics DVI DL 201 Tx User Manual

Dual link dvi transmitter and receiver
Hide thumbs Also See for DVI DL 201 Tx:
Table of Contents

Advertisement

Using Pass-through Mode with DDC Routed to a Local Monitor

1.
Set the EDID Minder switch to the off (down) position and the Default
EDID switch to the off (down) position (see the figure at right). The
position of the Remote DDC switch is not relevant.
2.
Connect the source device to the transmitter input.
3.
Connect the display device to the receiver output and, if required, the
local monitor to the transmitter output.
4.
Connect the transmitter to the receiver with the three twisted pair cables.
Transmitter port 1 connects to receiver port 1.
z
Transmitter port 2 connects to receiver port 2.
z
Transmitter port 3 connects to receiver port 3.
z
5.
Power on the local monitor, the transmitter, and the receiver.
6.
Boot up the source device. The source boots with the resolution and refresh rate of
the local monitor.
NOTE:
7.
Power on the display device.
NOTE:

Using Pass-through Mode with DDC Routed to the Remote Display

NOTE:
NOTE:
1.
Set the EDID Minder switch to the off (down) position and the Remote DDC switch to
the on (up) position (see the figure at right). The position of the Default EDID switch is
not relevant.
2.
Connect the source device to the transmitter input.
3.
Connect the display device to the receiver output and, if required, the
local monitor to the transmitter output.
4.
Connect the transmitter to the receiver with the three twisted pair cables.
Transmitter port 1 connects to receiver port 1.
z
Transmitter port 2 connects to receiver port 2.
z
Transmitter port 3 connects to receiver port 3.
z
5.
Power on the remote display, the transmitter, and the receiver.
Because the local monitor is the source of EDID, it must be powered on
before the source device is booted.
The remote display device must be capable of handling a resolution equal
to or greater than that of the local monitor.
This is the factory default setting.
Although DDC can be routed to the remote display, there may be
instances when the signals become corrupted or weak. In those cases, the
source device may be unable to boot up correctly.
DVI DL 201 Tx/Rx • Configuration and Operation
ON
ON
1 2 3
OFF
ON
ON
1 2 3
OFF
15