Setup controller COM Port:
7.6. Get the Power Supply Address
Every Genesys™ power supply has a serial COMM port address which is a number from 0 to 30. In order
to open communication to a power supply, the addressing command "ADDR nn" must be sent.
To see your power supply's serial address, go to the front panel of the supply and:
A.
B.
C.
If the "REM/LOC" LED is illuminated, briefly press and release the REM/LOC button to
put the supply into Local mode.
If the button does not respond, the supply has been set to Local Lockout.
In this case, cycle the AC power and try again.
Press and hold the REM/LOC button for three seconds.
See the front panel shows the serial address and "USb".
Remember this address for the next step.
In this picture, the address is 6 (the factory default).