Download Print this page
Crestron MPI-WP100 Installation Manual
Crestron MPI-WP100 Installation Manual

Crestron MPI-WP100 Installation Manual

Media presentation wall plates - international versions mpi-wp series

Advertisement

Quick Links

Crestron MPI-WP Series
Media Presentation Wall Plates - International Versions

Installation Guide

Further Inquiries
If you cannot locate specific information or have questions after reviewing this
guide, please take advantage of Crestron's award winning customer service
team by calling Crestron at 1-888-CRESTRON [1-888-273-7876]. For assistance
in your region, please refer to the Crestron Web site (www.crestron.com) for a
listing of Crestron worldwide offices.
You can also log onto the online help section of the Crestron Web site
(www.crestron.com/onlinehelp) to ask questions about Crestron products.
First-time users will need to establish a user account to fully benefit from all
available features.
Future Updates
As Crestron improves functions, adds new features and extends the capabilities
of the MPI-WP units, additional information may be made available as manual
updates. These updates are solely electronic and serve as intermediary
supplements prior to the release of a complete technical documentation revision.
Check the Crestron Web site periodically for manual update availability and its
relevance. Updates are identified as an "Addendum" in the Download column.
Crestron Electronics, Inc.
15 Volvo Drive Rockleigh, NJ 07647
Tel: 888.CRESTRON
Fax: 201.767.7576
www.crestron.com
DESCRIPTION
Media Presentation Wall Plates complete the total Crestron
end-to-end Crestron quality for every installation. A range of wall plates is offered to
support all types of analog and digital video, audio, and control signals.
The MPI-WP international version wall plates are designed to fit both European
(DIN 49073) and UK (BS 4662) electrical boxes (not included), and are finished using
decorative face plates (not included). Requires an FP-INTENSE or FP-PURE face plate,
available in 18 colors and finishes up to 5-gang in size.
Typical Application (MPI-WP130 Shown)
R G
A u
Installation Guide - DOC. 7168A
Specifications subject to
change without notice.
package, ensuring
®
B
d i o
PROJECTOR
D IO
A U
A u
d i o
LAPTOP
V G
A
R G
B
Media Presentation Wall Plate Models
MODEL
MPI-WP100
Three gold-plated RCA connectors, color-coded and labeled for
composite video and stereo audio. Bulkhead type feed-thru
connectors are used, providing female RCA connections at the rear
MPI-WP120
Five gold-plated RCA connectors, color-coded and labeled for
component video and stereo audio. Bulkhead type feed-thru
connectors are used, providing female RCA connections at the rear
MPI-WP130
One female DB15HD connector (i.e., HD-15, DE-15) and one 3.5 mm
mini-TRS connector, labeled for computer VGA and stereo audio. A
bulkhead type feed-thru connector is used, providing a female DB15HD
connection at the rear. Audio wiring is connected via a 3-pin terminal
block
MPI-WP131
One female DB15HD connector (i.e., HD-15, DE-15) and one 3.5 mm
mini-TRS connector, labeled for computer VGA and stereo audio. A
breakout cable assembly at the rear provides five BNC connections. Audio
wiring is connected via a 3-pin terminal block
MPI-WP150
One Type A HDMI
for HDMI and stereo audio. A bulkhead type feed-thru connector is used,
providing a female HDMI connection at the rear. Audio wiring is connected
via a 3-pin terminal block
MPI-WP160
One DisplayPort connector and one 3.5 mm mini-TRS connector, labeled
for DisplayPort and stereo audio. A bulkhead type feed-thru connector is
used, providing a female DisplayPort connection at the rear. Audio wiring is
connected via a 3-pin terminal block
MPI-WP181-C
One female 8-pin RJ-45 shielded connector labeled for DigitalMedia 8G+
Punch-down terminals at the rear facilitate installation using DM-CBL-8G
DigitalMedia 8G™ Cable or CAT5e
MPI-WP182
One female 8-pin RJ-45 connector labeled for QuickMedia
type feed-thru connector is used, providing a female RJ-45 and terminal
block connections at the rear
MPI-WP183
One female 8-pin RJ-45 connector labeled for Ethernet. A bulkhead type
feed-thru connector is used, providing a female RJ-45 connection at the
rear
MPI-WP187-S
A single female SC type optical fiber connector, labeled for DigitalMedia
8G
SC connection at the rear
MPI-WP190
One 4-pin 3.5mm detachable terminal block, labeled for Cresnet
A paralleled terminal block connection is provided at the rear
1.
Requires 68 mm minimum mounting depth.
2.
Some cables and connectors may necessitate additional mounting depth.
3.
Requires 85 mm minimum mounting depth.
4.
Requires 47 mm minimum mounting depth.
INSTALLATION
Installation of the Media Presentation Wall Plates consists of the following:
1. Select an appropriate wall plate location (wall, furniture, rack panel).
2. Using the supplied template, cut a hole in the mounting surface.
3. Install required electrical box (not provided).
(2030796)
4. Run and terminate cables. Refer to the wiring information on this page as
07.11
necessary.
5. Test cables prior to screwing down the wall plate.
6. Screw the wall plate to the electrical box.
7. Attach face plate to the mounting surface.
NETWORK WIRING GUIDELINES
Cresnet
. When wiring the Cresnet network, consider the following:
®
Use Crestron Certified Wire.
• Use Crestron power supplies for Crestron equipment.
Provide sufficient power to the system.
CAUTION: Insufficient power can lead to unpredictable results or damage to the
equipment. Please use the Crestron Power Calculator to help calculate how much power
is needed for the system. (www.crestron.com/calculators).
DM
Network. When wiring the DM network, consider the following:
®
NOTE: DMNet
wiring and Cresnet wiring are not compatible.
®
For DigitalMediaCAT wiring, use DM-CBL DigitalMedia™ cable, CresCAT-D, or quality
CAT5e/CAT6 cable. Do NOT use low-skew cable. For complete wiring guidelines, refer
to the latest revision of the Crestron DigitalMedia Design Guide (Doc. 4789), which is
available from the Crestron Web site (www.crestron.com/dmresources).
QuickMedia
. When wiring the QuickMedia network, consider the following:
®
NOTE: Do not untwist the two wires in a single pair for more than 1/3-1/2" (8-12 mm)
when making a connection. The twists are critical to canceling out interference between
the wires.
The aggregate cable length of a signal path originating at a QM transmitter and
terminating at a QM receiver must not exceed 450 feet (137 meters).
DESCRIPTION
.
1, 2
connector and one 3.5 mm mini-TRS connector, labeled
®
.
1, 2
.
2, 3
.
2, 4
.
2, 4
.
2, 4
fiber. A bulkhead type feed-thru connector is used, providing female
.
1, 2
.
1, 2
.
1, 2
.
1, 2
.
. A bulkhead
®
control.
®
.
2

Advertisement

loading
Need help?

Need help?

Do you have a question about the MPI-WP100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Crestron MPI-WP100

  • Page 1: Installation Guide

    2, 4 MPI-WP187-S A single female SC type optical fiber connector, labeled for DigitalMedia You can also log onto the online help section of the Crestron Web site fiber. A bulkhead type feed-thru connector is used, providing female ™ (www.crestron.com/onlinehelp) to ask questions about Crestron products.
  • Page 2: Return And Warranty Policies

    White/Orange White/Blue CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in Orange Green any application other than that for which it was intended or if it has been subjected to misuse,...

This manual is also suitable for: