SMART STORAGE HEATER:
SSH optimizes the energy management and consumption and provides the heat demand requested by the user in each period of
time reaching the desired comfort.
Smart charging control
SSH allows optimizing the energy management and consumption using a linear regression model based on the temperature
registered in the core of SSH to determine the current % of the storage heater charge and use this information to charge only
the heat necessary to supply the daily heat demand and avoid unnecessary energy consumption.
The charge level is monitored every time by the electronic control and represented in the display by the dots in the right side of
the display. 5 dots represent a fully charge storage heater.
i
While SSH is charging, the last dot is flashing at the top right part of the display.
Protection for excess of temperature in the room
In order to achieve maximum savings and avoid unnecessary energy consumption, if, during the charging period, the temperature
in the room exceeds the temperature set up in SSH for that room, then the charging will be interrupted until the temperature in
the room decreases.
Charge correction
The % of the storage heater charge is corrected automatically by SSH software. If working hours of balance resistance is higher
than a certain value, storage heater charge will be increased by a certain %. On the other hand, if balance resistance working
hours does not exceed this value, storage heater charge level is reduced by the same %.
This behaviour adapts the consumption to the real thermal needs, allowing the maximum level of energy savings at the required
comfort. The set-up temperature is independent of the Storage Heater level of charge. Initial setting for charge is 80%. This value
can be modified by entering "General Settings" part and modify the initial % of storage charge according to UP01 setting.
Smart discharge
If the energy discharged with natural convection is not enough to satisfy the heat demand of the room where SSH is installed, an
emitter incorporated in the SSH body will be connected providing additional heating to the room if necessary to supply the heat
demand of the room. The maximum working period of the emitter during on-peak electric electric periods can be adjusted and
cancelled by modifying UP08 parameter. (please go to "General Settings").
i
When the emitter is on, the symbol
*Storage Heater and Balance heater will never work at the same time.
Open Window Detection
With open window detection activated, the fan assisted discharge and the balance resistance working will be disconnected
automatically when a sharp decrease in temperature in the room is detected avoiding energy wastage.
i
When Open Windows Detection function is working, the icon
Adaptive Start Control
With adaptive start control activated, SSH electronic control analyses the heating requirements of the room where it is installed
using this information to turn on the emitter in advance in order to reach the set point temperature at the desired time.
i
When Adaptive Start Control function is working, the icon
is displayed.
13
Current Charge Level
is displayed.
is displayed.