Mitsubishi Electric MELSERVO-JE MR-JE-70A Instruction Manual page 52

Servo amplifier mr-je-_a series
Table of Contents

Advertisement

3. SIGNALS AND WIRING
Device
Symbol
Forward rotation
RS1
selection
Reverse rotation
RS2
selection
Speed selection
SP1
1
Speed selection
SP2
2
Speed selection
SP3
3
Connector
pin No.
This is used to select a servo motor torque generation directions.
The following shows the torque generation directions.
(Note) Input device
RS2
0
0
1
1
Note. 0: Off
1: On
1. For speed control mode
This is used to select the command speed for operation.
(Note) Input device
SP3
0
0
0
0
1
1
1
1
Note. 0: Off
1: On
2. For the torque control mode
This is used to select the limited speed for operation.
(Note) Input device
SP3
0
0
0
0
1
1
1
1
Note. 0: Off
1: On
Function and application
Torque generation direction
RS1
0
Torque is not generated.
Forward rotation in power
1
running mode/reverse rotation
in regenerative mode
Reverse rotation in power
0
running mode/forward rotation
in regenerative mode
1
Torque is not generated.
Speed command
SP2
SP1
0
0
VC (Analog speed command)
Pr. PC05 Internal speed
0
1
command 1
Pr. PC06 Internal speed
1
0
command 2
Pr. PC07 Internal speed
1
1
command 3
Pr. PC08 Internal speed
0
0
command 4
Pr. PC09 Internal speed
0
1
command 5
Pr. PC10 Internal speed
1
0
command 6
Pr. PC11 Internal speed
1
1
command 7
Speed limit
SP2
SP1
0
0
VLA (Analog speed limit)
0
1
Pr. PC05 Internal speed limit 1
1
0
Pr. PC06 Internal speed limit 2
1
1
Pr. PC07 Internal speed limit 3
0
0
Pr. PC08 Internal speed limit 4
0
1
Pr. PC09 Internal speed limit 5
1
0
Pr. PC10 Internal speed limit 6
1
1
Pr. PC11 Internal speed limit 7
3 - 23
Control
I/O
mode
division
P
S
T
DI-1
DI-1
DI-1
DI-1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents