Mitsubishi Electric MELSERVO-JE MR-JE-70A Instruction Manual page 160

Servo amplifier mr-je-_a series
Table of Contents

Advertisement

5. PARAMETERS
No./
Setting
symbol/name
digit
PC22
_ _ _ x
For manufacturer setting
*COP1
_ _ x _
Function
_ x _ _
selection C-1
x _ _ _
Encoder cable communication method selection
Select the encoder cable communication method.
0: Two-wire type
1: Four-wire type
If the setting is incorrect, [AL. 16 Encoder initial communication error 1] or [AL. 20
Encoder normal communication error 1] occurs.
PC23
_ _ _ x Servo-lock selection at speed control stop
*COP2
Select the servo-lock selection at speed control stop.
Function
In the speed control mode, the servo motor shaft can be locked to prevent the shaft
selection C-2
from being moved by an external force.
0: Enabled (servo-lock)
1: Disabled (no servo-lock)
_ _ x _ For manufacturer setting
_ x _ _ VC/VLA voltage averaging selection
Select the VC/VLA voltage average.
This is used to set the filtering time when VC (Analog speed command) or VLA
(Analog speed limit) is imported.
Set 0 to vary the speed to voltage fluctuation in real time. Increase the set value to
vary the speed slower to voltage fluctuation.
x _ _ _ Speed limit selection at torque control
Select the speed limit selection at torque control.
0: Enabled
1: Disabled
Do not use this function except when configuring an external speed loop.
PC24
_ _ _ x In-position range unit selection
*COP3
Select a unit of in-position range.
Function
0: Command input pulse unit
selection C-3
1: Servo motor encoder pulse unit
_ _ x _ For manufacturer setting
_ x _ _
x _ _ _ Error excessive alarm level unit selection
Select a setting unit of the error excessive alarm level set in [Pr. PC43].
0: 1 rev unit
1: 0.1 rev unit
2: 0.01 rev unit
3: 0.001 rev unit
The operation to maintain the stop position is performed.
The stop position is not maintained.
The control to make the speed 0 r/min is performed.
Setting
Filtering time [ms]
value
0
0
1
0.444
2
0.888
3
1.777
4
3.555
5
7.111
Function
5 - 33
Initial
Control mode
value
P
S
T
[unit]
0h
0h
2h
0h
0h
0h
0h
0h
0h
0h
0h
0h

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents