3. SIGNALS AND WIRING
(2) For 1-phase 200 V AC to 240 V AC power supply of MR-JE-10A to MR-JE-70A
1-phase
200 V AC to
240 V AC
Forced stop 2
(Note 3)
Servo-on
Note 1. MR-JE-40A and MR-JE-70A have a built-in regenerative resistor. (factory-wired) When using the regenerative option,
refer to section 11.2.
2. For the encoder cable, use of the option cable is recommended. For selecting cables, refer to "HF-KN/HF-SN Servo
Motor Instruction Manual".
3. This diagram shows sink I/O interface. For source I/O interface, refer to section 3.9.3.
4. For connecting servo motor power wires, refer to "HF-KN/HF-SN Servo Motor Instruction Manual".
5. Use a magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of
contacts) of 80 ms or less. Depending on the power supply voltage and operation pattern, bus voltage can decrease.
This can shift the mode to the dynamic brake deceleration during forced stop deceleration. When dynamic brake
deceleration is not required, slow the time to turn off the magnetic contactor.
6. Configure a circuit to turn off EM2 when the power is turned off to prevent an unexpected restart of the servo amplifier.
7. Connecting a servo motor of the wrong axis to U, V, W, or CN2 of the servo amplifier may cause a malfunction.
8. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However,
they can be configured by one.
POINT
Connect the 1-phase 200 V AC to 240 V AC power supply to L1 and L3. One of
the connecting destinations is different from MR-E Super Series Servo
Amplifier's. When using MR-JE as a replacement for MR-E Super, be careful not
to connect the power to L2.
EMG stop switch
(Note 5)
MCCB
MC
(Note 1)
(Note 6)
Power
supply
24 V DC (Note 8)
OFF
ON
RA1
MC
Malfunction
Servo amplifier
CNP1
L1
Built-in
U
L2
regenerative
resistor
V
L3
W
P+
C
(Note 7)
CN2
CN1
EM2
CN1
SON
DOCOM
ALM
DICOM
3 - 4
MC
SK
Servo motor
(Note 4, 7)
U
Motor
V
W
(Note 2)
Encoder
Encoder cable
24 V DC (Note 8)
Malfunction
RA1
M
(Note 3)