4. STARTUP
f) Travel distance unit selection
Select with the option buttons whether the travel distance set in c) is in the command pulse
unit or in the encoder pulse unit.
When the command input pulse unit is selected, the value, which is the set travel distance
multiplied by the electronic gear, will be the command value. When the encoder pulse unit is
selected, the travel distance is not multiplied by the electronic gear.
g) Enable repeat operation
To perform repeat operation, click the check. The initial setting and setting range for the repeat
operation are listed below.
To perform continuous operation with the repeat pattern and dwell time settings, which are set
by referring to the above table, click the check box of "Make the aging function enabled".
h) Forward/reverse the servo motor
Click the "Forward CCW" button to rotate the servo motor in the forward rotation direction.
Click the "Reverse CW" button to rotate the servo motor in the reverse rotation direction.
i) Pause the servo motor
Click the "Pause" button during servo motor rotation to temporarily stop the servo motor.
This button is enabled during servo motor rotation.
h) Stop the servo motor
Click the "Stop" button during servo motor rotation to stop the servo motor.
k) Forced stop
Click the "Forced stop" button during servo motor rotation to make a sudden stop.
This button is enabled during servo motor rotation.
l) Operation status
The operation status during the repeat operation, and the number of operations are displayed
m) Axis No.
Axis No. in operation is displayed.
n) Termination of positioning operation window
Click the close button to cancel the positioning operation mode and close the window.
(b) Status display
The status display can be monitored during positioning operation.
Item
Fwd. rot. (CCW) to rev. rot.
Repeat pattern
Dwell time [s]
Number of operations
[times]
4 - 35
Initial setting
Fwd. rot. (CCW) to rev. rot.
Fwd. rot. (CCW) to fwd. rot.
(CW)
Rev. rot. (CW) to fwd. rot.
Rev. rot. (CW) to rev. rot.
2.0
1
Setting range
(CW)
(CCW)
(CCW)
(CW)
0.1 to 50.0
1 to 9999