SMA Solar Technology AG
13.2.2.3 External/Backup (230#)
231# General
No.
Name
231.01
PvFeedTmStr
231.02
PvFeedTmStp
231.03
ExtLkTm
231.06
ExtSrc
231.12
ClstPwrNom
232# Grid Control
No.
Name
232.01
Country
232.02
GdVtgMin
Operating Manual
Description
Start time for PV grid feed-
in in hh:mm:ss (expert
mode)
Stop time for PV grid feed-
in in hh:mm:ss (expert
mode)
Lock time until connection
to the external grid after
reverse power or relay
protection in minutes (ex-
pert mode)
External energy sources in
Off-Grid mode
Nominal power of the
cluster in kW
Description
Set country standard
(protected by
SMA Grid Guard)
Lower minimum thresh-
old of line voltage for
voltage monitoring in V
(expert mode, pro-
tected by
SMA Grid Guard)
13 Parameters in Sunny Remote Control
Value
Explanation
00:00:00 to
23:59:59
00:00:00 to
23:59:59
0 min to
60 min
PvOnly
Only AC sources in
the stand-alone grid,
no generator in the off-
grid system
Gen
Generator
Grid
Utility grid
GenGrid
Electric generator or
utility grid
–
Value
Explanation
Other
Individual setting
VDE-AR-4105
Code of Practice
VDE-AR-N 4105
AS4777
Standard AS4777
172.50 V to
230 V / 50 Hz
210.01 InvVt-
gNom
220 V / 60 Hz
SI30M-44M-60H-80H-BE-en-33
Default
Value
–
✖ ✓ 04:00:00
–
✖ ✓ 22:00:00
–
✖ ✓ 20 min
✖ ✓
–
✓ ✓
Default
Value
✓ ✓
✓ ✓ 184.00
V
194.00
V
–
–
–
–
129