Battery Category - SMA SUNNY ISLAND 3.0M Operating Manual

Sunny remote control
Hide thumbs Also See for SUNNY ISLAND 3.0M:
Table of Contents

Advertisement

SMA Solar Technology AG
Name
Description
Timed start
Time-controlled operation

13.1.2 Battery Category

Display Pages
Name
Description
StateOfCha
Current battery state of charge in %
rge
Voltage
Battery voltage in V
PowerOut
Current discharge power of the battery in kW
Mode
Current charging process
Remain time Remaining time of current charging process in h-
h:mm:ss
Next equal
Remaining time until next equalization charge in -
days
Health
Ratio of currently usable capacity to nominal ca-
(SOH)
pacity, in %
Cycle
Nominal energy throughputs of the battery
A nominal energy throughput is the calculated re-
sult of one full charge and discharge of the bat-
tery.
Operating Manual
13 Parameters in Sunny Remote Control
Value
Explanation
Disable
Disables time-controlled op-
eration.
Enable
Enables time-controlled op-
eration.
Value
Explanation
If the value is positive, the
battery is discharging. If the
value is negative, the bat-
tery is charging.
Boost
Boost charge is enabled.
Full
Full charge is enabled.
Float
Float charge is enabled.
Equalize
Equalization charge is en-
abled.
Silent
The Sunny Island has
switched to energy-saving
mode.
SI30M-44M-60H-80H-BE-en-33
✖ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
103

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sunny island 6.0hSunny island 4.4mSunny island 8.0h

Table of Contents