3.2

Rated data at a mains voltage of 230 V

3.2.1
Operation with rated power (normal operation)
Typical motor power
Three−phase asynchronous motor
(4−pole)
8200 motec
Mains voltage
Data for operation at 1/N/PE AC 230 V
Rated mains current
Rated output current at
2 kHz
switching frequency
4 kHz
8 kHz
16 kHz
Max. permissible output
2 kHz
current for 60 s at
4 kHz
1)
switching frequency
8 kHz
16 kHz
Output voltage
Power loss (operation with I
)
N8
Dimensions
Weight
Bold print = data for operation at a switching frequency of 8 kHz (Lenze setting)
1)
Currents for periodic load change: 1 min overcurrent time with I
2)
Under different operating conditions possible for some types: Operation with increased rated output current with the same load change
cycle (^ 3−6)
Fuses and cable cross−sections
8200 motec
Type
System
[kW]
1/N/PE AC
E82MV251_2B
0.25
180 ... 264 V;
E82MV371_2B
0.37
45 ... 65 Hz
1)
Only use UL−approved cables, fuses, and fuse holders.
UL fuse: voltage 240 V, tripping characteristic "H", "K5" or "CC"
2)
Pulse current sensitive or universal−current sensitive earth−leakage circuit breaker
Observe national and regional regulations
L
Rated data at 230 V mains voltage
P
[kW]
N
P
[hp]
N
Type
U
[V]
mains
I
[A]
mains
2)
I
[A]
N24
I
[A]
N8
I
[A]
N16
I
[A]
max24
I
[A]
max8
I
[A]
max16
U
[V]
M
P
[W]
v
L x W x H [mm]
m [kg]
Installation acc. to EN 60204−1
Fuse
Circuit breaker
M10 A
M10 A
Technical data
0.25
0.34
E82MV251_2B
1/N/PE AC 180 V − 0 % ... 264 V + 0 % ; 45 Hz − 0 % ... 65 Hz + 0 %
3.4
2.0
1.7
1.1
2.5
2.5
1.6
3~ 0 ... U
mains
30
190 x 138 x 100
1.8
and 2 min base load time with 75 % I
max
Normal operation
L1, L2, L3, PE
2
[mm
]
C10 A
1.5
C10 A
1.5
0.37
0.5
E82MV371_2B
5.0
2.9
2.4
1.6
3.6
3.6
1.4
/ 0 ... 650 Hz
40
1.8
Nx
1)
Installation acc. to UL
Fuse
L1, L2, L3, PE
[AWG]
10 A
16
10 A
16
EDB82MV752 EN 5.2
FI
³ 30 mA
2)
3−5