Leica Nova MS60 User Manual page 57

Multistation
Hide thumbs Also See for Nova MS60:
Table of Contents

Advertisement

Next Step
MS60/TS60, Check & Adjust
Step
Description
6.
Measure to measure and to continue to the next screen.
180°
008702_001
7.
Face II measurement
Measure to measure the same target in the other face.
If Calibrate the telescope camera has been checked, aim at the same target
accurately with the telescope camera using the view finder and the digital
crosshair on the display. Measure measure to the target and to calculate the
instrument errors.
If one or more errors are bigger than the predefined limits, the procedure
must be repeated. All measurements of the current run are rejected and
none of them is averaged with the results from previous runs.
8.
Adjustment Status
Number of measurements: Shows the number of runs completed. One run
consists of a measurement in face I and face II.
l Component quality (1 σ): and similar lines show the standard deviations of
the determined adjustment errors. The standard deviations can be calcu-
lated from the second run onwards.
Measure at least two runs.
9.
Next to continue with the check & adjust procedure.
10.
Select Add another calibration loop if more runs have to be added. Next and
continue with step 4.
OR
Select Finish the calibration & store the results to finish the calibration
process. Next to view the adjustment results.
11.
Select Finish to accept the results. No more runs can be added later.
OR
Select Redo to decline all measurements and to repeat all calibration runs.
OR
Back returns to the previous screen.
IF the results are
to be stored
to be determined again
180°
THEN
If the Use status is set to Yes, Next overwrites the old
adjustment errors with the new ones.
Redo rejects all new determined adjustment errors and
repeats the whole procedure. Refer to paragraph
"Combined Adjustment Procedure Step-by-Step".
If Calibrate the telescope camera has
been checked, aim at the same target
accurately with the telescope camera
using the view finder and the digital
crosshair on the display. Measure to
measure and to continue to the next
screen.
The fine pointing has to be
performed manually in both faces.
57

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nova ts60

Table of Contents