Leica Nova MS60 User Manual page 66

Multistation
Hide thumbs Also See for Nova MS60:
Table of Contents

Advertisement

Atmospheric
conditions
Accuracy
Characteristics
MS60/TS60, Technical Data
Range A:
Strong haze, visibility 5 km; or strong sunlight, severe heat shimmer
Range B:
Light haze, visibility about 20 km; or moderate sunlight, slight heat
shimmer
Range C:
Overcast, no haze, visibility about 40 km; no heat shimmer
Measurements can be made to reflector tapes over the entire range without external
ancillary optics.
Accuracy refers to measurements to standard prisms.
For TS60 - R1000:
Distance
std. dev.
measuring mode
ISO 17123-4,
standard prism
Precise
0.6 mm + 1 ppm*
Standard
1 mm + 1 ppm
Fast
2 mm + 1 ppm
Continuously
3 mm + 1 ppm
Averaging
1 mm + 1 ppm
Beam interruptions, severe heat shimmer and moving objects within the beam path
can result in deviations of the specified accuracy.
*
Atmospheric conditions type C, range up to 1000 m, GPH1P reflector
**
Target aligned to instrument
For MS60 - R2000:
Distance
std. dev.
measuring mode
ISO 17123-4,
standard prism
Standard
1 mm + 1.5 ppm
Fast
2 mm + 1.5 ppm
Continuously
2 mm + 1.5 ppm
Averaging
1 mm + 1.5 ppm
Beam interruptions, severe heat shimmer and moving objects within the beam path
can result in deviations of the specified accuracy.
*
Target aligned to instrument
**
Auto point application increases the measurement time
Type:
Carrier wave:
Measuring system:
std. dev.
ISO 17123-4,
tape**
1 mm + 1 ppm
1 mm + 1 ppm
3 mm + 1 ppm
3 mm + 1 ppm
1 mm + 1 ppm
std. dev.
ISO 17123-4,
tape*
1 mm + 1.5 ppm
3 mm + 1.5 ppm
3 mm + 1.5 ppm
1 mm + 1.5 ppm
Coaxial, visible red laser
658 nm
R1000: System Analyzer Basis 100 MHz - 150 MHz
R2000: Wave Form Digitizer
Measurement
time, typical [s]
7
2.4
2.0
< 0.15
-
Measurement
time, typical [s]
1.5
1.0
>0.05**
-
66

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nova ts60

Table of Contents