Gate, Latch, and Sampling Modes
Normal Gate Mode
Control input IN1 (start/stop)
External or internal (word n, bit 03)
Current counter value (words n+7 and n+6)
Counting flag (word n+4, bit 00)
1, 2, 3... 1.
Cumulative Gate Mode (C200H-CT002 Only)
Control input IN1 (reset)
External or internal
(word n, bit 03)
Control input IN2
(count pulse)
External or internal
(word n, bit 04)
Current counter value
(Words n+7 and n+6)
Counting flag
Word n+4, bit 00
1, 2, 3... 1.
1
0
1
0
Counting starts from 0 on rising edge of IN1.
2.
Counting stops on falling edge of IN1. The counter value at that time is
retained until the next IN1 signal. No external outputs are supported by
the gate mode.
1
0
1
0
É É É É É É É É É É
É É É É
É É É É É É É É É É
É É É É É É É É É É
É É
É É É É É É É É É É
1
0
The current counter value is reset to zero on the leading edge of IN1.
2.
Counting continues from the last current counter value on rising edge of
IN2.
3.
Counting stops on falling edge of IN2. The counter value at that time is
retained until the next IN1 signal. No outputs are supported by the gate
mode.
1
2
É É É É É É É É É É
É É É É É É É É É É
É É É É É É É É É É É É É É É É É É
É É É É É É É É É É
Section 4-4
1
2
É É É É É É É É
É É É É É É É É
É É É É É É É É
É É É É É É É É
67