Preset Mode
Error Location
Error Code
Count Overflow Flag
Reset Flag
Current Counter Value
Output Flags
occurred, information on other errors can be output to IR word n+5 by again set-
ting READ ERROR.
Word n+5, bit 07 through 00
The error location gives the rightmost two digits of the DM address, i.e., the bit
number, where the data causing the error is stored.
Word n+5, bit 15 through 08
Error codes indicate the nature of the error and are given in Appendix A Error
Code List.
Word n+4, bit 06
The count overflow flag is turned ON when the counter value is incremented
passed 8,388,607. This flag turns OFF when the next counting operation is
started.
Word n+4, bit 07
The reset flag turns ON for one PC cycle time after the Counter Unit is reset.
Word n+6 and n+7
The current counter value is accessible in words n+6 and n+7 as 6 BCD digits
with a sign digit. In preset mode, the sign digit is always 0 (+).
Word n+4 bits, 15 through 08
Output flag bits are ON whenever the corresponding output is ON. Output flags
turn ON regardless of the status of ENABLE OUTPUT (word n, bit 02). Refer to
4-3-1 Data Allocation for specific flag bits.
Section 4-3
59