Linear and Circular Modes
DM Area Settings
DM 1100
DM 1101
DM 1102
DM 1103
DM 1110
DM 1111
DM 1112
DM 1113
DM 1114
DM 1115
DM 1116
DM 1117
DM 1118
DM 1119
DM 1120
DM 1121
DM 1122
DM 1123
DM 1124
Program
Start switch
Reset switch
0
2
0
0
0
0
0
7
4
9
9
9
0
0
0
0
1
0
0
0
0
0
0
0
1
0
1
0
0
0
0
0
0
0
8
0
4
3
0
0
0
0
0
0
0
2
0
0
0
0
0
0
0
0
4
2
0
6
0
0
0
0
0
0
3
1
0
0
0
0
0
0
0
0
C
0
11401
11006
Input Z
Outputs #1, #6, and #7 are directly output from the Counter Unit.
Sets the mode to 1 (linear).
Enables ranges #0, #1, #2, and #3.
Sets the maximum counter value to 4,999.
(The counter values change as follows : 0,
1,...4998, 4999, 0, 1,...)
Range #0 (work piece at station 1)
Lower limit: 1000; upper limit: 1010
Output pattern specifies that output #7 be turned
ON when the counter value is within range #0
Range #1 (work piece at station 2)
Lower limit: 4300; upper limit: 200 (0 is spanned)
Output pattern specifies that outputs #1 and #6
be turned ON when the counter value is within
range #1
Range #2 (work piece at transfer point)
Lower limit: 600; upper limit: 3100
Output pattern specifies that outputs #6 and #7
be turned ON when the counter value is within
range #2.
START and ENABLE OUTPUT
11000
are ON while the start switch is
ON.
11002
The Counter Unit is reset on
the rising edge of the input Z
11006
immediately after the counter
reset switch is pressed.