Electrical Heat - Minimum Fan Speed; Electric Heat Performance Data: 208/230-1-60 & 208/230-3-60 - York AVC18BX21 Technical Manual

Avc series single piece variable speed ecm communicating air handlers for use with split-system cooling & heat pumps
Table of Contents

Advertisement

5151060-YTG-F-1116

ELECTRICAL HEAT - MINIMUM FAN SPEED

Heater Kit
Nom. kW
1,2,3
@240V
Models
6HK(0,1)6500206
2.4kW
Med Lo (D) Med Lo (D) Med Lo (D) Med Lo (D) Med Lo (D) Med Lo (D) Med Lo (D) Med Lo (D) Med Lo (D) Med Lo (D)
6HK(0,1)6500506
4.8kW
Med Lo (D) Med (C)
6HK(0,1)6500806
7.7kW
6HK(0,1)6501006
9.6kW
6HK36501025
6HK(1,2)6501306 12.5kW
6HK(1,2)6501506
14.4kW
6HK36501525
6HK(1,2)6501806
17.3kW
6HK36501825
6HK(1,2)6502006
19.2kW
6HK46502025
6HK(1,2)6502506
24kW
6HK46502525
1. (0,1) - 0 = no service disconnect OR 1 = with service disconnect.
2. (1,2) - 1 = with service disconnect, no breaker jumper bar OR 2 = with service disconnect & breaker jumper bar.
3. 6HK3 = 3-Phase with terminal block connectors only, 6HK4 = 3-Phase with service disconnect.
ELECTRIC HEAT PERFORMANCE DATA: 208/230-1-60 & 208/230-3-60
Heater
1,2,3
Models
6HK(0,1)6500206
6HK(0,1)6500506
6HK(0,1)6500806
6HK(0,1)6501006
1PH
6HK(1,2)6501306
6HK(1,2)6501506
6HK(1,2)6501806
6HK(1,2)6502006
6HK(1,2)6502506
6HK36501025
6HK36501525
3PH
6HK36501825
6HK46502025
6HK46502525
1. (0,1) - 0 = no service disconnect OR 1 = with service disconnect.
2. (1,2) - 1 = with service disconnect, no breaker jumper bar OR 2 = with service disconnect & breaker jumper bar.
3. 6HK3 = 3-Phase with terminal block connectors only, 6HK4 = 3-Phase with service disconnect.
4. For different power distributions, see conversion table on Page 5.
6
18B
24B
30B
Med (C) Med Lo (D) Med (C) Med Lo (D) Med Lo (D) Med Lo (D) Med Lo (D) Med Lo (D)
Med (C) Med Hi (B) Med Hi (B) Med Lo (D) Med Hi (B) Med (C) Med Lo (D) Med Lo (D) Med Lo (D) Med Lo (D)
Med (C) Med Hi (B) Med Hi (B) Med Lo (D) Med Hi (B) Med (C) Med Lo (D) Med Lo (D) Med Lo (D) Med Lo (D)
Med Hi (B) Med Hi (B)
Med Hi (B) Med Hi (B) Med Hi (B)
Nominal kW
@240V
208V
2.4
1.8
4.8
3.6
7.7
5.8
9.6
7.2
12.5
9.4
14.4
10.8
17.3
13
19.2
14.4
24
18
9.6
7.2
14.4
10.8
17.3
13
19.2
14.4
24
18
Air Handler Models
36B
36C
42C
Med (C)
Med Hi (B) Med (C) Med Lo (D) Med Lo (D) Med Lo (D) Med Lo (D)
Hi (A)
Med Hi (B) Med Hi (B)
Hi (A)
Med Hi (B)
Hi (A)
Hi (A)
4
Total Heat
kW
MBH
230V
208V
230V
2.2
6.2
7.5
4.4
12.3
15
7.1
19.7
24.1
8.8
24.6
30.1
11.5
32
39.2
13.2
36.9
45.1
15.9
44.3
54.2
17.6
49.2
60.2
22
61.5
75.2
8.8
24.6
30.1
13.2
36.9
45.1
15.9
44.3
54.2
17.6
49.2
60.2
22
61.5
75.2
48C
48D
60C
Med (C)
Med (C) Med Lo (D) Med Lo (D)
Med (C)
Med Hi (B) Med (C)
Med Hi (B)
Hi (A)
Med Hi (B) Med Hi (B)
Hi (A)
kW Staging
W1 Only
208V
230V
208V
1.8
2.2
1.8
3.6
4.4
3.6
5.8
7.1
5.8
7.2
8.8
7.2
3.1
3.8
9.4
3.6
4.4
10.8
6.5
7.9
13
7.2
8.8
14.4
7.2
8.8
18
7.2
8.8
7.2
10.8
13.2
10.8
13
15.9
13
7.2
8.8
14.4
9
11
18
Johnson Controls Unitary Products
60D
Med (C)
Med Hi (B)
W1 + W2
230V
2.2
4.4
7.1
8.8
11.5
13.2
15.9
17.6
22
8.8
13.2
15.9
17.6
22

Advertisement

Table of Contents
loading