Single piece air handlers for use with split-system cooling & heat pumps
Hide thumbs Also See for AHP18:

Advertisement

TECHNICAL GUIDE
SINGLE PIECE AIR HANDLERS
FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS
MODELS: AHP18 THRU 60
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
ISO 9001
Certified Quality
Management System
DESCRIPTION
This fan coil line offers the ultimate in application flexibility. The
AHP (non-variable speed motor) models can be ordered upflow
only or as multi-position. The multi-position model can be
installed in downflow, upflow, horizontal right or left without the
need for additional field installed kits.
All UPG air handlers and coils utilize a TXV to provide our cus-
tomers with the optimum performance and refrigerant control
required for 13+ SEER systems. Air handlers can be ordered
with R410A TXV factory installed. Air handlers are also avail-
able with "Flex-coils" without a factory installed metering device.
For added flexibility, an R22 or R410A TXV can be field
installed to meet your refrigerant choice.
FEATURES
Thermal Expansion Valve - Provides the ultimate refrigerant
control required for today's high efficient product. The UPG bolt-
on TXV provides the added flexibility to convert the air handler
to the required refrigerant. The UPG TXV is a true bolt-on which
does not require brazing to replace or install.
Insulated Cabinet - All air handler cabinets are thermally insu-
lated with 1" foil faced insulation (R-4.2) to prevent sweating.
For applications in extreme humidity conditions an optional,
field installed, external insulating wrap kit is also available.
Factory - Sealed to achieve 2% or less leakage rate with or
without field installed filter at 1.0" water gauge external static
pressure.
Durable Finish Inside and Out - Air handler casings are made
of pre-painted galvanized steel which provides a better paint to
steel bond that resists corrosion and rust creep. All internal coil
sheet metal parts are made of G90 galvanized.
High Efficiency - 5 ton unit has high efficiency DC motor.
4 HK Heat Kit - Installation friendly, easy service, more robust,
unique to new design.
255029-YTG-M-0610

Advertisement

Table of Contents
loading

Summary of Contents for York AHP18

  • Page 1 Management System Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com Additional rating information can be found at www.ahridirectory.org. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE DESCRIPTION This fan coil line offers the ultimate in application flexibility.
  • Page 2 DIMENSIONS BLOWER COMPARTMENT DRAIN CONNECTIONS REFRIGERANT CONNECTIONS 7-11/32” 1-1/2” FILTER ACCESS Dimensions MODELS Height Width AHP18B3XH21 17.5 AHP18B4FH21 AHP24B3XH21 17.5 AHP24B4FH21 AHP30B3XH21 AHP30B4GH21 17.5 AHP30B4HH21 AHP30B4FH21 AHP36C3XH21 AHP36C4GH21 AHP36C4HH21 AHP36C4FH21 AHP42C3XH21 AHP42C4HH21 AHP48D3XH21 AHP48D4HH21 24.5 AHP48D4JH21 AHP60D3XH21 24.5 AHP60D4JH21 1. Actual size (Conduit size). H indicates 4 position model.
  • Page 3: Coil Technical Data

    255029-YTG-M-0610 COIL TECHNICAL DATA Models Application Conn. Types AHP18B3XH21 Cooling / Heat Pump AHP18B4FH21 AHP24B3XH21 Cooling / Heat Pump AHP24B4FH21 AHP30B3XH21 AHP30B4GH21 Cooling / Heat Pump AHP30B4HH21 AHP30B4FH21 AHP36C3XH21 AHP36C4GH21 Cooling / Heat Pump AHP36C4HH21 AHP36C4FH21 AHP42C3XH21 Cooling / Heat Pump AHP42C4HH21 AHP48D3XH21 Cooling /...
  • Page 4 ACCESSORIES Refer to Price Manual for specific model numbers. TXV Kits - TXV kits are available for “Flex-coil” applications and converting R22 to R410A or as a service replacement. All kits are bolt-on and require no brazing to install. Non-Combustible Bases - A combustible floor base accessory is available, if required by local codes, when the air handler is installed in the downflow position on a combustible material.
  • Page 5: Application Factors - Rated Cfm Vs. Actual Cfm

    255029-YTG-M-0610 AIR FLOW DATA - 60 Hz MODELS Blower Models Motor Speed High AHP18B**H21 Medium High AHP24B**H21 Medium High AHP30B**H21 Medium High AHP36C**H21 Medium High AHP42C**H21 Medium High AHP48D**H21 Medium High / #1 Medium High / #2 AHP60D**H21 Medium / #3 Medium Low / #4 Low / #5 1.
  • Page 6: Physical & Electrical Data

    PHYSICAL & ELECTRICAL DATA Models Blower - Diameter x Width Motor Nominal RPM Voltage Amps Full Load (230) Type Size Filter Permanent Type Kit Shipping / Operating Weight (lbs.) - N Models Shipping / Operating Weight (lbs.) - H Models Models Blower - Diameter x Width Motor...
  • Page 7: Kw & Mbh Conversions - For Total Power Input Requirement

    255029-YTG-M-0610 ELECTRICAL DATA - 208/230-1-60 Heater Models Models* 4HK*6500206 AHP18B**H21 4HK*6500506 4HK*6500806 4HK*6500206 4HK*6500506 AHP24B**H21 4HK*6500806 4HK*6501006 4HK16501306 4HK*6500506 4HK*6500806 4HK*6501006 AHP30B**H21 4HK16501306 4HK165N1506 4HK*6500506 4HK*6500806 AHP36C**H21 4HK*6501006 4HK16501506 4HK16501806 4HK*6500506 4HK*6500806 4HK*6501006 AHP42C**H21 4HK16501506 4HK16501806 4HK16502006 4HK*6500506 4HK*6500806 4HK*6501006 AHP48D**H21 4HK16501506 4HK16501806...
  • Page 8 ELECTRICAL DATA (FOR SINGLE SOURCE POWER SUPPLY) - COPPER WIRE 208/230-1-60 Heater Models Models* 4HK*6500206 AHP18B**H21 4HK*6500506 4HK*6500806 4HK*6500206 4HK*6500506 AHP24B**H21 4HK*6500806 4HK*6501006 4HK16501306 4HK*6500506 4HK*6500806 AHP30B**H21 4HK*6501006 4HK16501306 4HK165N1506 4HK*6500506 4HK*6500806 AHP36C**H21 4HK*6501006 4HK16501506 4HK16501806 4HK*6500506 4HK*6500806 4HK*6501006 AHP42C**H21 4HK16501506 4HK16501806 4HK16502006...
  • Page 9 255029-YTG-M-0610 ELECTRICAL DATA (FOR MULTI SOURCE POWER SUPPLY) - COPPER WIRE 208/230-1-60 Heater Models Models AHP24B**H21 4HK16501306 4HK16501306 AHP30B**H21 4HK165N1506 4HK16501506 AHP36C**H21 4HK16501806 4HK16501506 AHP42C**H21 4HK16501806 4HK16502006 4HK16501506 AHP48D**H21 4HK16501806 4HK16502006 4HK16501506 4HK16501806 AHP60D**H21 4HK16502006 4HK16502506 1. O.C.P. = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay fuse. ELECTRICAL DATA - 208/230-3-60 Heat Kit - Models...
  • Page 10: Cooling Models With Electric Heat Wiring

    ELECTRICAL DATA (FOR SINGLE SOURCE POWER SUPPLY) - COPPER WIRE 208/230-3-60 Heat Kit - Models Three Phase AHP24B**H21 4HK06501025 4HK06501025 AHP30B**H21 4HK065N1525 4HK06501025 AHP36C**H21 4HK06501525 4HK06501025 AHP42C**H21 4HK06501525 4HK06501825 4HK06501025 AHP48D**H21 4HK06501525 4HK06501825 4HK06501025 AHP60D**H21 4HK06501525 1. O.C.P. = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay fuse. 2.
  • Page 11: Typical Applications

    255029-YTG-M-0610 CONTROL WIRING - AHP or MA Series Air Handler Single Stage H/P with Standard Demand Defrost Control Board THERMOSTAT W / W1 X / L SINGLE-STAGE COOLING WIRING * Optional dehumidification humidistat switch contacts open on rise. Notes: 1. “Y” Terminal on Air Handler Control Board must be connected for full CFM and applications requiring 60 second blower off delay for SEER enhancement.
  • Page 12 Subject to change without notice. Published in U.S.A. 255029-YTG-M-0610 Copyright © 2010 by Johnson Controls, Inc. All rights reserved. Supersedes: 255029-YTG-L-0708 Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069...

Table of Contents