York AHR18B3XH21 Technical Manual

York AHR18B3XH21 Technical Manual

Single piece air handlers for use with split-system cooling & heat pumps
Hide thumbs Also See for AHR18B3XH21:

Advertisement

TECHNICAL
TECHNICAL
GUIDE
GUIDE
SINGLE PIECE AIR HANDLERS
FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS
MODELS: AHR18 THRU 60*
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at:
www.upgnet.com
Additional rating information can be found at:
www.ahridirectory.org
WARRANTY
Standard 5-year limited parts warranty.
Extended 10-year limited parts warranty when product is regis-
tered online within 90 days of purchase for replacement or
closing for new home construction.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
This fan coil line offers the ultimate in application flexibility. This unit
may be used for upflow, downflow, horizontal right, or horizontal left
applications.
All JCI Unitary Products air handlers and coils use a TXV to provide our
customers with the optimum performance and refrigerant control. Air
handlers are shipped with "Flex-coils" without a factory installed meter-
ing device. For added flexibility, an R-22 or R-410A TXV or orifice can
be field installed to meet your refrigerant choice.
FEATURES
Thermal Expansion Valve -
trol required for today's high efficient product. The UPG bolt-on TXV
provides the added flexibility to convert the air handler to the required
refrigerant. The UPG TXV is a true bolt-on which does not require braz-
ing to replace or install.
Insulated Cabinet -
with 3/4" foil faced insulation to prevent sweating.
Factory Sealed -
duct blaster field test conditions for system airflow verification.
Durable Finish Inside and Out -
pre-painted galvanized steel which provides a better paint to steel bond
that resists corrosion and rust creep. All internal coil sheet metal parts
are made of G60 galvanized or prepainted G30 galvanized.
Filters -
thick standard size filters.
Electric Heat Kits -
available for installation friendly and easy service applications.
ISO 9001
Certified Quality
Management System
Provides the ultimate refrigerant con-
All air handler cabinets are thermally insulated
Achieves 2% or less total airflow leakage rate at
Air handler casings are made of
All models have internal filter racks provided for use with 1"
6HK series of field installed electric heat kits are
1055361-BTG-D-0514

Advertisement

Table of Contents
loading

Summary of Contents for York AHR18B3XH21

  • Page 1 1055361-BTG-D-0514 DESCRIPTION TECHNICAL TECHNICAL This fan coil line offers the ultimate in application flexibility. This unit may be used for upflow, downflow, horizontal right, or horizontal left applications. GUIDE GUIDE All JCI Unitary Products air handlers and coils use a TXV to provide our customers with the optimum performance and refrigerant control.
  • Page 2: Dimensions & Duct Connection Dimensions

    Cooling /Heat Pump Sweat (2) 22 x 17.5 1 x 0.866 Enhanced AHR48D Cooling /Heat Pump Sweat (2) 24 x 17.5 1 x 0.866 Enhanced AHR60D Cooling /Heat Pump Sweat (2) 28 x 17.5 1 x 0.866 Enhanced Johnson Controls Unitary Products...
  • Page 3: Cooling Capacity

    56.5 46.6 35.4 23.3 70/57 43.5 39.5 34.0 28.4 AHR48D 85/72 102.3 90.1 76.1 60.5 80/67 83.7 71.5 57.3 43.6 1610 75/62 67.0 54.0 41.2 27.0 70/57 50.9 46.6 39.8 33.4 (For notes see page 4.) Johnson Controls Unitary Products...
  • Page 4: Application Factors - Rated Cfm Vs. Actual Cfm

    For a power distribution voltage that is different than the provided nominal voltage, multiply the kW and MBH data from the table by the conversion factor in the following table. DISTRIBUTION POWER NOMINAL VOLTAGE CONVERSION FACTOR 208V 240V 0.75 220V 240V 0.84 230V 240V 0.92 Johnson Controls Unitary Products...
  • Page 5: Electrical Data - Cooling Only

    1. (0,1) - 0 = no circuit breaker OR 1 = with circuit breaker. 2. (1,2) - 1 = with circuit breaker, no breaker jumper bar OR 2 = with circuit breaker & breaker jumper bar. 3. For different power distributions, see conversion table on Page 4. Johnson Controls Unitary Products...
  • Page 6 3. MOP = Maximum Overcurrent Protection device; must be HACR type circuit breaker or time delay fuse. 4. Stated sizes are for 75°C, copper wire only. If wire other than non-plated, 75°C ambient, copper wire is used, consult applicable tables of the NEC and local codes. Johnson Controls Unitary Products...
  • Page 7 3. The 20kW and 25kW heater models (6HK16502025 and 6HK16502525) come with circuit breakers standard. Single source power MCA and MOP requirements are given here only for reference if used with field installed single point power modification. Johnson Controls Unitary Products...
  • Page 8: Typical Applications

    Voltage Range HEAT 208/230-1-60 187-253 HORIZONTAL LEFT 1. Rated in accordance with ARI Standard 110, utilization range “A”. Airflow must be within the minimum and maximum limits approved for electric heat, evaporator coils and outdoor units. Johnson Controls Unitary Products...
  • Page 9: Typical Thermostat Connections

    1055361-BTG-D-0514 TYPICAL THERMOSTAT CONNECTIONS Johnson Controls Unitary Products...
  • Page 10: Air Flow Data (Cfm)

    1120 1065 1005 High 1579 1511 1399 1273 1145 1068 AHR34C Medium 1108 1057 High 1470 1390 1325 1245 1155 1045 AHR36B Medium 1325 1265 1205 1125 1025 1115 1075 1025 (For notes see page 11.) Johnson Controls Unitary Products...
  • Page 11 Airflow data shown is from testing performed at 230V. AHE units use a X13 motor, and there is minimal variation of airflow at other distribution voltage values. The above data can be used for airflow at other distribution voltages. Johnson Controls Unitary Products...
  • Page 12 NOTES Subject to change without notice. Published in U.S.A. 1055361-BTG-D-0514 Copyright © 2014 by Johnson Controls, Inc. All rights reserved. Supersedes: 1055361-BTG-C-0214 York International Corp. 5005 York Drive Norman, OK 73069...