6: Maintenance
6.8 Maintenance every 1500 hours
When using Sullair AWF
and replace the fluid filter element.
Refer to Section 6.9: Parts replacement and adjustment
procedures.
6.9 Parts replacement and
adjustment procedures
6.9.1
Compressor fluid change procedure
Warm-up the compressor for 5 to 10 minutes to warm the
fluid. Shut the compressor off and relieve all internal
44
®
, change the compressor fluid
Figure 6-1: Running gear lubrication
Subject to EAR, ECCN EAR99 and related export control restrictions.
pressure before proceeding. Drain the fluid by opening
the appropriate drain valve located in the frame at the
front of the machine. Close the valve when draining is
complete. Change the compressor fluid and replace the
fluid filter element. For element replacement: See Sec-
tion 6.9.4: Main fluid filter servicing on page 46. Fill the
receiver tank with fluid according to Section 3.2: Lubrica-
tion guide—compressor on page 30.
6.9.2
Running gear lubrication
Refer to Figure 6-1. An inspection of the running gear
should be made on a routine basis.
02250203-986 R03
E900H User Manual