12. Insert the bolt provided through the mounting bracket and the
heater handle; tighten with the nut and washer.
Wall Mount
13. Loosen the screw to remove the inspection window cover in the
rear of the heater.
14.Run the electrical power supply cable in flexible conduit and
connect to the wiring compartment via the knock-out at back
side of the unit.
15. Make the connections properly with connectors which are
suitable for the conductor size, including grounding wirings. And
after making the connections, arrange the pigtail leads of unit
and power supply wires in the wiring compartment.
16. You can use the inside or wall thermostat. If you use the inside
thermostat, press the rock switch to INSIDE THERMOSTAT.
17. If you want to use the wall thermostat (Not included), press the
rock switch to WALL THERMOSTAT, and insert the two wall
Ceiling Mount