3.3.2

Isolated Output

Each of the 16 isolated digital output channels comes equipped with a MOSFET.
Every eight output channels share common emitters and integral suppression diodes
for inductive load, activated by connecting PCOM to VDD. (Channels 0~7 use
PCOM1. Channels 8~15 use PCOM2.)
If the external voltage (5~40V) is connected to each isolated output channel (IDO)
and its isolated digital output turns on (200mA per channel maximum), the card's cur-
rent will sink from the external voltage.