3-2. AIF CLOCK

Aug. 2012
This feature allows controls to be set for periods of the day that
block the automatic "Filter Now" prompts. For example, the
controls could be set not interrupt with "Filter Now" prompts
during the lunch rush, and during the supper rush. But, if filter-
ing is desired during this time, press and hold a
access the filter menu.
Each AIF Blocking period is defined by a start time (a time of
day, XX:XX A, etc) and a duration in minutes.
Weekdays M-F are all grouped together. Up to four different
AIF blocking periods may be programmed throughout the day
for Monday - Friday. (All days share the same settings.)
A separate set of four blocking periods may be programmed
for Saturdays, and a final set of four blocking periods may be
programmed for Sundays.
1. Press and hold
shows in the display, followed by ENTER CODE.
2. Enter code 1, 2, 3, 4 (first 4 product buttons). "PRODUCT"
and "SELECTN" show in the displays.
3. Press ▼ button once and "AIF CLOCK" show in
displays.
4. Press √ button and use ◄ and ► buttons to scroll
through "ENABLE" and "DISABLE" and then press √
button again to select one.
5. If "ENABLE" is chosen, then ▲ and ▼ buttons can be
used to scroll through following list of blocking periods:
Left Display
M-F 1
M-F 2
M-F 3
M-F 4
SAT 1
SAT 2
SAT 3
SAT 4
SUN 1
SUN 2
SUN 3
SUN 4
3-3
Model LVG-202, 203, 204
and
buttons until LEVEL - 1
Right Display
XX:XX A XX
XX:XX A XX
XX:XX A XX
XX:XX A XX
XX:XX A XX
XX:XX A XX
XX:XX A XX
XX:XX A XX
XX:XX A XX
XX:XX A XX
XX:XX A XX
XX:XX A XX
button to