Setting the Conditions of Communications with the PC/Host by Using the Memory Switches
3-5-4

Setting RS-232C Communication Conditions (NT20S-ST128)

82
When using an NT20S-ST128 (using the RS-232C interface for communication
with the host), set the following communication conditions.
S Data Bits
S Stop Bits
S Parity Check
S Flow Control
S Baud Rate
Set the same communication conditions at the host and the NT20S. You are rec-
ommended to set the highest baud rate that can be used by the host and NT20S.
The factory settings are as follows:
S Data Bits
8bits
S Stop Bits
2bits
S Parity Check
Even
S Flow Control
None
S Baud Rate
9600bps
Set the conditions of the communication with the Host by the menu operation from
the System Menu as mentioned below.
[ SYSTEM MENU ]
Quit
Transmit Mode
Maintenance Mode
[ MAINTENANCE MENU ]
Quit
PT Setting
I/O Check
Init. Memory
Memory Switch
DIP-SW Status
Section 3-5
Select "Maintenance Mode".