Replacing The Terminal Block; Removing The Terminal Block; Installing The Terminal Block - Emerson Rosemount 8750W Reference Manual

Magnetic flowmeter platform for utility, water, and wastewater applications
Hide thumbs Also See for Rosemount 8750W:
Table of Contents

Advertisement

Reference Manual
00809-0300-4750, Rev CA
8.5

Replacing the terminal block

8.5.1

Removing the terminal block

1.
2.
3.
8.5.2

Installing the terminal block

1.
2.
3.
4.
Figure 8-5. Terminal Block
A
A. Terminal block
B. Coil and electrode lead wires
Maintenance
Disconnect power to the transmitter and the remote cabling connected to the
terminal block.
To disconnect the terminal block from the junction box housing, remove the two
mounting screws and the two divider mounting screws (if applicable).
Remove the coil and electrode wire clips.
Connect the coil and electrode clips to the new terminal block.
Press the terminal block into its keyed position, and tighten the two mounting
screws. Install the divider with the two mounting screws (if applicable).
Reconnect remote cabling and replace junction box cover.
Reconnect power to the transmitter.