2.3 Connections

2.3.1 Power supply

230 Volt, 50 Hz,
Connected load 700W <=> 3.1 A (blind current compensation).
or 115V, 60 Hz
Connected load 700W <=> 6.2 A (blind current compensation).
Please see printing on the case for the right Power supply !

2.3.2 DMX

DMX 512 Standard input/output. See also printing on the case for the right
pin assignment.
[+] = Pin 3 / [-] = Pin 2 / [Ground] = Pin 1
The DMX- Addressing starts at the DMX- Address [001].

2.4 Fuse

The
Y
P
O
C
5
Y
P
O
C
5
230V / T 5A (EU model)
Please see the printing on the
Attention:
• Disconnect AC outlet before changing a fuse!
• Use only the original declared fuse type!
GLP
German Light Production
7
5 electronic system is protected by a 5x20 mm fuse.
7
5
or 115V / T 10A (US model)
Y
Y
P
O
C
5
7