  • Page 3: Table Of Contents

    Table of contents Description of Device....................5 1.1 Safety Instructions ....................6 Preparation and Installation ...................7 2.1 Mounting......................7 2.1.1 Clamps ....................7 2.1.2 Mounting plate..................8 2.2 Secure the O ................8 2.3 Connections......................9 2.3.1 Power supply..................9 2.3.2 DMX .......................9 2.4 Fuse........................9 The Menu Field ......................10 (D001) 3.1 Adjust the DMX- Address ..............11...
  • Page 4 DMX Channel Selection (DMX Protocol) .............18 Changing the Lamp....................22 5.1 Safety Regulations..................22 5.2 Realize the Lamp Change ................22 5.3 Lamp adjustment ....................23 Changing a Gobo ....................24 6.1 Safety Regulations..................24 6.2 Realize the Gobo Change ................24 Maintenance and Cleaning the O ..........25 7.1 Safety Regulations..................25 7.2 Circumference and Interval (rule-of-thumb) ............25 7.3 Cleaning the Optical System ................26...
  • Page 5: Description Of Device

    Description of Device 1. Moving Head 2. Carrying handles 3. Base casing 4. Arm 5. Up- button 6. Down- button 7. Enter- button 8. Mode- button DMX IN DMX OUT POWER 210V~ FUSE: 230V~ T3.15A 250V~ LAMP: 50Hz MSD 250W 9.
  • Page 6: Safety Instructions

    1.1 Safety Instructions O is a High-Tech Product. To guarantee a smooth operation, it is necessary to keep following rules. The manufacturer of this device will not take responsibility of damages through disregard of the information in this manual. Warranty adjustments will be cancelled. 1.
  • Page 7: Preparation And Installation

    Preparation and Installation 2.1 Mounting O is fully operational whether it hangs or is mounted to the wall. It can also be operated while standing on the floor. Keep a safety distance of 0.5 m towards any easy inflammable materials (decoration etc.). Install a safety wire that can hold at least 10 times the weight of the fixture.
  • Page 8: Mounting Plate

    a) Camlock system: This system allows you a fast and efficient setup of clamps. Attach the two camlocks to the designated position C1 and C2 on the backside of the case and close the locks by turning them 90°. 106.0 Verify the secure fit of the camlock system.
  • Page 9: Connections

    2.3 Connections 2.3.1 Power supply 230 Volt, two-pin earthed plug 50 Hz, Connected load 500W <=> 2,2 A (blind current compensated). 2.3.2 DMX DMX 512 Standard input/output. See also printing on the case for the right pin assignment. [+] = Pin 3 / [-] = Pin 2 / [Ground] = Pin 1 The DMX- Addressing starts at the DMX- Address [001].
  • Page 10: The Menu Field

    The Menu Field You’ll find the control board on the side part of the base. It allows you to LED-Display make all necessary adjustments of the . With the Mode-key you get into the main menu. Afterwards you can navigate through the menu with the Up/Down-keys.
  • Page 11: Adjust The Dmx- Address

    (D001) 3.1 Adjust the DMX- Address Right after turning on the O you can see the current DMX- Address. If there is no DMX- Signal the display flashes. D001 For the address setting please follow this procedure: 1. Switch On the O and wait until the fixture reset has finished RESE ' is flashing in the display).
  • Page 12: Lamp On/Off (Lamp)

    If you want to run the systems simultaneously, one of the s must be switched as the master. All others must be "Slave" Master = OFF. Notice: The Audio function is only working if no DMX is connected. This function can work e.g. on small events or as an emergency program.
  • Page 13: Invert Tilt Movement (Rtlt)

    (RTLT) 3.8 Invert Tilt Movement RTLT This function allows you to invert the Tilt movement. Use the Up/Down-keys to select invert . Press Enter to confirm or Mode to cancel. (SPEC) 3.9 Special Functions SPEC This menu allows you to enter further special functions of the In detail they are: (MANU) 3.9.1 Manual Drive...
  • Page 14: Lamp Off Via Dmx (Dlof)

    the lamp automatically after switching on the fixture or if you don't want this function. Press Enter to confirm or Mode to cancel and return to the menu. If you have chosen you have the possibility to start the lamp either via DMX or direct at the O in the Lamp menu.
  • Page 15: Display (Disp)

    (DISP) 3.9.5 Display DISP Use this function to choose between different display indications. Use the Up/Down-keys to select desired function and press Enter to confirm or Mode to cancel and return to the menu. D ON Display On/Off (If you've chosen , the display will go out with- in 15 seconds after the last input.
  • Page 16: Adjustments And Calibrations

    In addition to these settings, you can set to fan speed to minimum via DMX (Special channel, DMX value 224..229). This will last until a temperature of 90° is reached. (ADJU) 3.9.8 Adjustments and Calibrations ADJU By this function you can adjust and calibrate the positions of the different wheels and other motors.
  • Page 17: Feedback (Feed)

    Function Display Default Settings DMX Address D001 D001 Pan reverse RPAN Tilt reverse RTLT Automatic lamp on LAAU Lamp on via DMX DLOF Display DISP D ON Cooling fan FANS HIGH LOOF LOHI Feedback FEED (FEED) 3.9.10 Feedback FEED O is provided with a automatic position correction (feedback) for the Pan and Tilt movement.
  • Page 18: Dmx Channel Selection (Dmx Protocol)

    This message informs you that one of the fixture function wasn’t able to RsER do its reset correct (magnetic sensor, stepping motor, driver on the PCB, cables, etc.). Repair the defect and start the fixture again. DMX Channel Selection (DMX Protocol) Channel Function Time and Value...
  • Page 19 Channel Function Time and Value color 6 / color 7 (slow) 90..91 5A..5B 35,5 color 7, Yellow (slow) 92..93 5C..5D 36,3 color 7 / color 8 (slow) 94..95 5E..5F 37,1 color 8, Cyan (slow) 96..97 60..61 37,8 color 8 / color 9 (slow) 98..99 62..63 38,6...
  • Page 20 Channel Function Time and Value Gobo 8 (fast) 28..31 1C..1F 11..12 Gobo 9 (fast) 32..35 20..23 13..13,9 Gobo 10 (fast) 36..63 24..3F 14..24,9 Gobo 1 (open, fast) 64..65 40..41 25..25,9 Gobo 1 (open, slow) Chaser from gobo to 66..67 42..43 26..26,9 gobo max.
  • Page 21 Channel Function Time and Value Gobo-shake +/- 30° 3,5 moves / min. up to 48..63 30..3F 19..24 slow – fast 60 moves / max. Color-chaser C / C+1 0,7 BPS ... 2,3 BPS 64..79 40..4F 25..31 slow – fast => 1,43 s ... 0,43 s Color-chaser C / C+2 0,7 BPS ...
  • Page 22: Changing The Lamp

    Changing the Lamp For a frictionless operation pleas read this chapter carefully and follow all instructions. 5.1 Safety Regulations • Pull out the main plug! • Wait min. 20 minutes after the last operation to cool down the fixture. • Don’t touch the bulb of the lamp with bare fingers (this can cause damages). •...
  • Page 23: Lamp Adjustment

    5.3 Lamp adjustment The optimum distance between the lamp and the lens must be controlled after every lamp change. The lower deviation amount is min. 1.0mm. Running the fixture within a lower deviation can cause damages of lamp and/or lens. min.
  • Page 24: Changing A Gobo

    Changing a Gobo O is fitted with standard gobos (outside diameter 27 mm, image size 23 mm). You can use ether steel or glass gobos. 6.1 Safety Regulations • Pull out the main plug! • Wait min. 20 minutes after the last operation to cool down the fixture. •...
  • Page 25: Maintenance And Cleaningleaning The Y P O Cleaning

    Magnet Open Wheel with rotating Gobos Wheel with non rotating/fixed Gobos Attention: If you use glass gobos, the non-vaporized side must be fitted towards the lamp direction. Maintenance and Cleaning the It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not built up on or within the fixture.
  • Page 26: Cleaning The Optical System

    Position Interval In this way Outside optic weekly soft cloth and glass cleaning fluid Color filter monthly soft cloth and glass cleaning fluid Gobos yearly vacuum cleaner, airbrush, etc. Glass gobos monthly soft cloth and glass cleaning fluid Prism monthly soft cloth and glass cleaning fluid Dimmer/Shutter/Iris yearly...
  • Page 27: Technical Specification

    Technical Specification Power supply 500 Watt, 2.2A (blind current compensated) Power consumption Model AC 230V / 50 Hz~ T 3.15A, 250V, 5x20 mm (fine-wire fuse) Fuse protection Lamp - MSD 250/2 Philips Types - CSD 250/2/SE GE - HSD 250/78 Osram, GY-9,5 socket 2000h Philips, 2000h GE, 3000h Osram Live time 8500k Philips, 8500k GE, 7800k Osram...
  • Page 28: Index

    Index Invert ............... 12 Adjustments........... 16 Lamp adjustment..........23 aspheric lens ........... 26 Audio..............11 Maintenance........... 25 BGV C1.............. 7 Manual Drive ........... 13 Measures ............27 Menu Field............10 Calibrations............ 16 Mounting............7 Camlock system ..........8 Mounting plate..........8 Change a Gobo ..........
  • Page 29: Annexes

    Annexes A) Chassis Ground WARNING: Use 2 clamps to rig the fixture. Lock the clamps to the attachment points Lock each clamp with M10 screw. Be sure that the screws are fully tight. For mounting-plate use points B1, B2. Use points C1 and C2 for omega-clamps with 1/4 turn fasteners. Be sure that the fastener is fully locked Safety chain/cord Vor Geb rau ch Anle itung lese n.
  • Page 30 Mounting positions for clamps (M10x20 mm) Wall mounting German Light Products GmbH (instruction version 1.05)
  • Page 31 DMX=0 DMX=255 DMX=0 DMX=255 DMX=127 PAN movement range (540°) TILT movement range (280°) German Light Products GmbH (instruction version 1.05)