3.4 Connections

Power
The AC supply shall provide earth ground connection and overload
protection. Before applying power, verify that there is adequate
clearance around the fixture, that there is no filter or other object on
the front glass, and that the head is unlocked and can move freely.
The JDC1 provides a 3-conductor, 20 A Neutrik powerCON TRUE1 socket for
connection to AC power. The autosensing power supply accepts 100-240 V,
50/60 Hz AC power. Do not connect to any other voltage or an external dimmer.
The main fuse is located in a holder in the base. WARNING! Always disconnect
the fixture from the mains supply before replacing the fuse. Replace only with
fuse of the specified type.
Control Data
The JDC1 provides 5-pin XLR input/output sockets for connection to a USITT DMX-
512 Standard data link. The pin connections are Pin 1 = [Ground] / Pin 2 = [-] /
Pin 3 = [+]. Pins 4 & 5 on the 5-pin sockets have no contact.

3.5 Start/stop operation

Verify that the tilt lock has been released before operating. Apply power to start
operation. Disconnect from power to stop operation.

3.6 Transportation and Storage

The JDC1 should be transported either in a flight case or its original packaging
to protect it from damage from shocks during transportation. Lock the head in
the horizontal position for transport by sliding the tilt lock lever to the locked
position.
When not installed, store the fixture in a dry location.