F5 Do-02 Set-Up - YASKAWA VS-616PS5 Series Programming Manual

Brushless motor drive
Hide thumbs Also See for VS-616PS5 Series:
Table of Contents

Advertisement

Section F: Option Parameters

F5 DO-02 Set-up

F5
DO-02 Set-up
F5-01 DO-02C Digital Output Channel 1 Selection
Setting Range:
Factory Default:
Selects the multi-function output selections for channel 1 of the DO-02C option.
Setting
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
10
11
For detailed information on these settings, refer to section H2, Digital Outputs.
F5-02 DO-02C Digital Output Channel 2 Selection
Setting Range:
Factory Default:
Use this function to select the multi-function output selections for channel 2 of the
DO-02C option.
56
0 to 37
During run 1 (setting = "0")
Description
During run 1 (factory default)
Zero speed
Sref/Sout agree 1
Sref/Sset agree 1
Speed detection 1
Speed detection 2
Inverter ready
DC bus undervoltage
Baseblock 1
Option reference
Remote operation
Torque detection 1 (N.O.)
Loss of reference
DB overheat
Fault
Not used
Minor fault
Reset command active
Same as F5-01
Zero speed (setting = "1")
Setting
Description
12
Timer output
13
Agree 2
14
Agree 2
15
Speed detection 3
16
Speed detection 4
17
Torque detection 1(N.C.)
18
Torque detection 2 (N.O.)
19
Torque detection 2 (N.C)
1A
Reverse direction
1B
Baseblock 2
1D
Regenerating
1E
Restart enabled
1F
Overload (OL1)
20
OH prealarm
30
Current/torque limit
31
Speed limit
37
During run 2
37
VS-616PS5 Programming Manual