Section T: Tuning Parameters

T1 Auto-tuning

T
Tuning Parameters
T1
Auto-tuning
Auto-tuning is required at the time of commissioning to allow the drive to determine
the angular displacement between the magnetic pole position and hall sensor/
encoder marker pulse position. This is necessary to insure optimum performance in
the Pm machine.
T1-02 Tuning Mode
The tuning mode is set in this parameter. Tuning is performed in the drive mode by
setting T1-02 = 2, and pressing the digital operator RUN key.
.
After auto-tuning is completed, the setting automatically returns to "0."
T1-03 Tuning Operation Selection
.
Setting
0
1
100
Setting
0
Normal running mode (factory default)
2
Auto-tuning mode
Auto-tuning procedures are performed on all parameters (under development.
Only PG origin pulse adjustment is performed (factory default).
Description
Description