5 To perform shutdown processing of the devices when a power failure occurs
5-1
The outline on the UPS monitoring software
5-2
Additional Information
Explanation of software functions
Function name
1.
Auto shutdown
2.
UPS monitoring
(operating status)
3.
UPS monitoring
(data)
4.
Pop-up notification
5.
Shutdown when
OS is inactive
6.
Schedule operation
7.
UPS setting
change
8.
External command
execution
9.
Event log save
10.
Data log save
11.
Coordinated shut-
down
12.
Output receptacle
control
13.
Redundant power
supply support
14.
Remote UPS
management
15.
Mail send
16.
SNMP manage-
ment
17.
Telnet connection
18.
SYSLOG support
Description
The computer can be shut down automatically when a problem
occurs with the power supply.
The operating status of the UPS can be monitored (in Commercial
Power Mode/Battery Mode).
Monitoring can be performed for input voltage value, connection
capacity, battery capacity, etc.
When a problem such as a power failure occurs, a pop-up window
that shows the details of the problem can be displayed.
Shutdown can be performed when the computer is in an inactive
state. The operating status is retained at shutdown in inactive
state, so operation details are not lost.
Schedule settings can be made for UPS stop/start.
UPS settings (beep ON/OFF, etc.) can be changed. (Items that
can be set vary according to the UPS.)
By executing commands at shutdown, items such as application
programs can be launched.
Information of events that occur on the UPS (power supply prob-
lems, setting changes, occurrences of failure, etc.) are saved as a
log.
Data of input/output voltage value, connection capacity, etc. is
periodically saved as a log (the save frequency can be set).
When a problem occurs with the power supply, multiple computers
connected to the UPS can coordinate to perform auto shutdown.
The UPS output receptacles can be individually set to ON/OFF.
Two or more UPS can be connected to computers equipped with
redundant power supply. Shutdown is not performed when a
power supply problem affects only one of the units. Shutdown is
performed only when a power supply problem occurs with both
UPS, so the system's operating rate is improved.
The UPS can be managed remotely from a computer on the
network.
When a problem such as a power failure occurs, a notification
email describing the problem can be sent to the system adminis-
trator.
UPS management information can be sent to the SNMP manager.
Settings such as shutdown parameters can be made via the Telnet
connection.
UPS management information can be recorded in SYSLOG.
BN50T/BN75T/BN100T/BN150T/BN220T/BN300T