After connecting to commercial power, make sure that the "INPUT PROTECTION" AC in-
put overcurrent protection switch is switched to the ON position on the back of the unit.
For the ON and OFF positions, refer to the illustration of the rear view in "1-3 Name of
each part".
Switch
AC Input overcurrent
protection switch
 Set the AC Input overcurrent protection switch to ON (factory setting) to enable the
AC Input Overcurrent Protection function.
When there are too many connected devices or there was a short-circuit with the
connected devices, the AC Input Overcurrent Protection function works.
 When the AC Input Overcurrent Protection function works, the AC Input overcurrent
protection switch automatically turns to OFF. In that event, disconnect all connected
devices, switch the AC input overcurrent protection switch ON, and then switch the
power switch on the unit back ON.
BN50T/BN75T/BN100T/BN150T/BN220T/BN300T
Settings
Function
OFF
The AC Input Overcurrent Protection function is disable.
ON (factory setting)
The AC Input Overcurrent Protection function is enable.
Notes
2 Installation and connection
2-3
Connecting the AC input