4 Maintenance and Inspection
4-2
Replacing the battery
7
Battery replacement is now complete.
4-12
Attach the front panel.
.
Attach the front panel to the unit. 1)
Use a screwdriver to securely tighten (clockwise) the 2 screws at the top of the front
panel. 2)
1)
Be sure to reset the battery life counter after replacing the battery.
 After replacing the battery, reset the battery life counter from the "Control" - "Reset
B.life counter" screen in the menu on the unit's LCD.
If you do not reset the battery life counter, a battery replacement alarm may occur
earlier than the expected battery life.
Write the battery replacement date on the included battery replacement date
label, and attach the label to the unit.
Or, enter the battery replacement date from the "Setting" - "Battery Settings" - "Battery
Installation" screen in the menu on the LCD.
Tighten the 2 screws.
2)
Notes