Decommissioning - frost protection

1. Switch off the machine - main switch to „0"- position
2. Cut off the water supply
3. Open the spray gun briefly until the pressure is released
4. Apply the safety catch on the spray gun
5. Remove the water hose and spray gun
6. Drain the pump: switch on the motor for approx. 20 seconds
7. Pull the plug from the socket
8. Clean HP hose and stow away
9. Clean water filter
Frost protection
The machine is normally still partially filled with water after work has been completed.
In case the high-pressure cleaner is exposed to frost:
To protect the appliance from frost, completely empty it of water:
Disconnect the machine from the water supply and switch off the ignition. Switch on the
master switch and open the gun. The pump now presses the remaining water out of the
water tank, the pump and the continuous-flow heater.
Do not allow the machine to run for longer than a minute without water.
If the machine is not in use for lengthy frosty periods of time, it is advisable to pump
anti-freeze into the machine: For this purpose, fill the antifreeze agent into the water
tank and switch on the machine without ignition. Wait with opened gun, until the agent
comes from the nozzle.
However, the best protection against frost is to keep the machine in a place that is
safe from frost.