2 Specifications
2.1 General Specifications
Environmental
Conditions
Mechanical
Operating
Conditions
Electrical
Operating
Conditions
Installation
Requirements
Item
Ambient Operating
Temperature
Ambient Storage
Temperature
Ambient Operating
Humidity
Ambient Storage
Humidity
Pollution Level
Corrosive Gas
Operating Altitude
Vibration
Resistance
Shock Resistance
Noise Resistance
Ground
Cooling Method
Specifications
0 to 55°C
-25 to 85°C
30 to 95% (with no condensation)
5 to 95% (with no condensation)
Pollution level 1 (conforming to JIS B 3501)
There must be no combustible or corrosive gas
2,000 m above sea level or lower
Conforming to JIS B 3502:
• 10 to 57 Hz with single-amplitude of 0.075 mm
• 57 to 150 Hz with fixed acceleration of 9.8 m/s
• 10 sweeps each in X, Y, and Z directions
(sweep time: 1 octave/min)
Conforming to JIS B 3502:
Peak acceleration of 147 m/s
each in the X, Y, and Z directions
Conforming to EN 61000-6-2, EN 55011 (Group 1,
Class A)
Power supply noise (FT noise): 2 kV min., for one
minute
Radiation noise (FT noise): 1 kV min., for one minute
Ground to 100 Ω Max
Natural convection cooling
2.1 General Specifications
2
2
(15 G) twice for 11 ms
9