4.10 P3SBCCCCCCCCMMMMMMMM [CHK]<CR>
 Description: Change the CAN configuration of CAN Converter module. This command will
save the CAN configuration parameter into SRAM. When the module is rebooted, the CAN
configuration will recover the previous setting.
 Syntax: P3SBCCCCCCCCMMMMMMMM[CHK]<CR>
P3
S
B
CCCCCCCC
MMMMMMM
Table: CAN baud rate list
B
0
1
2
3
4
5
6
7
8
9
 Response: A valid command will let the module to apply the CAN configuration parameters.
Invalid command: ?<Error Code><CR>
Note:
It is necessary to enable the "Error Response" function in the CAN Converter Utility, in order to
receive Syntax and/or communication error information at the host PC. This command does
not support user-defined CAN baud rate function. About CAN filter setting, please refer to
section 3.2.
This function is just supported by the firmware version 3.00 or more in I-7530 series and
I-7530, I-7530-FT, I-7530A, I-7565, tM-7530, tM-7530A User Manual
Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved
Command character
CAN Specification 2.0A/2.0B
CAN Baud rate
CAN filter acceptance code
CAN filter acceptance mask
10K baud rate of CAN
20K baud rate of CAN
50K baud rate of CAN
100K baud rate of CAN
125K baud rate of CAN
250K baud rate of CAN, I-7530-FT does not support
500K baud rate of CAN, I-7530-FT does not support
800K baud rate of CAN, I-7530-FT does not support
1000K baud rate of CAN, I-7530-FT does not support
83.3K baud rate of CAN, I-7530-FT does not support
Description