Tiiildd; Tiiil[Chk]<Cr - ICP DAS USA I-7530-G CR User Manual

I-7530 rs-232/can converter
Hide thumbs Also See for I-7530-G CR:
Table of Contents

Advertisement

4.1
tIIILDD...[CHK]<CR>
Description: Send or receive a standard CAN data frame.
Syntax: tIIILDD...[CHK]<CR>
t
III
L
DD...
Response: Valid command: No response
Note:
It is necessary to enable the "Error Response" function in the I-
7530 Utility, in order to receive Syntax and/or communication error
information at the host PC.
Example:
Command: t03F6112233445566<CR>
Send a CAN message with a standard data frame. ID=03F, DLC=6,
data1=11, data2=22, data3=33, data4=44, data5=55 and data6=66.
4.2
TIIIL[CHK]<CR>
Description: Send or receive a standard CAN remote frame.
Syntax: TIIIL[CHK]<CR>
T
III
L
Response: Valid command: No response
Note:
It is necessary to enable the "Error Response" function in the I-
7530 Utility, in order to receive Syntax and/or communication error
information at the host PC.
I-7530 RS-232/CAN Converter User's Manual (Version 2.5, Mar/2012) ------------- 28
Represent a standard (2.0A) data frame.
11 bits Identifier (000~7FF)
Data length (0~8)
Input data frame value according to the data length
(00~FF)
Invalid command: ?<Error Code><CR>
Represents a standard (2.0A) remote frame.
11 bits Identifier (000~7FF)
Data length (0~8)
Invalid command: ?<Error Code><CR>