ICP DAS USA I-7530 User Manual page 31

I-7530 series uart to can bus converter
Hide thumbs Also See for I-7530:
Table of Contents

Advertisement

the UART message is none, the UART timeout is useful. After receiving one character
from the UART interface, the CAN converter will not transfer the data until the time of the
UART timeout passes.
About details of the pair connection, please refer to the Appendix E for reference.
Save and default value button:
After finishing the configuration, users can click the button "Save All Setting" to save the
configuration in to the EEPROM of the CAN converter. If users would like to recover the
parameters to the factory default, click "Load Default Setting" button to recover all of the
configuration parameters to be default value. Afterwards, users can use the button "Save All
Settings" to save the default parameters in to the EEPROM of the CAN converter.
The default values of the parameters of the CAN converter are shown below.
RS-232: RS-232 Baud rate = 115200/921600(for I-7565)
Data Bit
Stop Bit
Parity
Add Checksum
Error Response
TimeStamp Response = No
CAN:
CAN Specification
CAN bus Baud rate
Acceptance Code
Acceptance Mask
Communication:
Mode: Normal
I-7530, I-7530-FT, I-7530A, I-7565, tM-7530, tM-7530A User Manual
Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved
= 8
= 1
= None
= No
= No
= 2.0A
= 125K
= 000
= 000
Version 1.4