Item
iSCSI name
Error recovery level
Header digest
Data digest
Maximum iSCSI
connections at one time
CHAP
Appendix D: iSCSI standards and specifications
Hitachi Virtual Storage Platform G800 Hardware Reference Guide
Specification
3
4
Both iqn
and eui
types
are supported
0 (zero)
Supported
Supported
255 per iSCSI port
Supported
iSCSI specifications
Comments
following if changing
values:
The setting of the
corresponding host
should also be changed
to log in the new port
number.
The new port number
might conflict with other
network communication
or be filtered on some
network equipment,
preventing the storage
system from
communicating through
the new port number.
The unique iqn value is
automatically set when a
target is made. iSCSI name
is configurable.
Error recovery by retrying
from host. Does not
support Level 1 and Level
2.
Detects header error or
data error with iSCSI
communication. The
storage system follows the
host's digest setting. If
digest is enabled, the
performance degrades.
The amount of the
degradation depends on
factors such as host
performance of host and
transaction pattern.
N/A
Authentication: login
request is sent properly
from host to storage. CHAP
is not supported during
discovery session.