Unpack And Inspect; Figure 5: Levelmaster Group D Hazardous Location Installation - ABB LevelMaster 7100 User Manual

Liquid level sensor with batteryless float support
Hide thumbs Also See for LevelMaster 7100:
Table of Contents

Advertisement

When connecting to Totalflow equipment (flow computers or remote controllers), PCCU32 software is required. Adding and
setting up the LevelMaster application is required for communication between the Totalflow devices and the LevelMaster.
Hazardous locations installation requirements
In addition to general requirements in section 3.1.3, above, the installation and grounding of the LevelMaster in hazardous
locations require the following:
Intrinsically safe Totalflow CSA-certified barrier board
Grounding must meet the requirements as specified in the National Electrical Code (NEC) or the Canadian Electrical Code
(CEC).
LevelMaster sensors are CSA-certified for installations in hazardous locations when connected through Totalflow CSA-certified
barrier boards in accordance with the Totalflow certification drawings (see Figure 5).
Class 1, Division 1, Group D when connected through Totalflow CSA-certified barrier boards. One barrier board supports up
to four level sensors, with a maximum distance of 500 feet.
Class 1, Division 1, Group C, D when connected through Totalflow CSA-certified barrier boards . One barrier board
supports up to three level sensors, with a maximum distance of 500 feet.
IMPORTANT NOTE: Figure 5 shows the barrier enclosure (not the actual barrier board). The barrier board
required depends on the location classification. Two board options are available for Class 1, Division 1 locations.
For Group D, barrier boards must be part number 2100336-001. For Group C and D, barrier boards must be part
number 2100336-002. Barrier boards are sold with their enclosure. Replacement barrier board kits are also
available. Contact ABB for details.

Unpack and inspect

The LevelMaster is shipped in a specially designed shipping carton which contains the sensor unit, electronics board with
enclosure, mounting components, parts list, wiring and interconnect diagrams. If an intrinsically safe barrier is provided, it and its
associated hardware are shipped in a separate carton.
IMPORTANT NOTE: If there is any damage to the shipping carton, keep the carton and packing materials until the
contents are inspected and found to be damage-free.
1.
Inspect all of the shipping cartons for damage.

Figure 5: LevelMaster Group D hazardous location installation

LevelMaster 7100 User manual 2105835 Rev AA | 11