of the board's centerline as shown in Figure 20. Pt.C extends a minimum distance of "C"
from the tip end of the board as shown in Figure 20. The width distance "W" on either side
of Pt.C is given in CHART 1 and shown in Figure 20.
BOARD MINIMUM CLEARANCE AREA
POOL TYPE
I
II
III
IV
V
See Article 5 contained in ANSI/APSP/ICC -5 2011 STANDARD FOR
RESIDENTIAL INGROUND SWIMMING POOLS and refer to Figure 3
and Table 1 for Minimum Water Envelope Dimensions AB, BC and
Width at Point C.
"C"
DIMENSION FOR BOARD
"W"
DIMENSION FOR BOARD
B. The minimum clearance area of a slide or diving board shall not intersect any coping or rope
and float line. (See Figure 20) The minimum clearance area of a slide or diving board may
intersect each other provided that they are not used simultaneously.

ELECTRICAL BONDING

If electrical bonding is required by the local governmental regulations, it shall be done in accordance
with Article No. 680 of the current National Electrical Code or the local Code, whichever has
jurisdiction. Five (#24) 1/4" x 1/2" Sheet Metal Screws and five (#10) 1/4" x 3/4" Flat Washers are
provided for this purpose. Secure one per slide leg and one per ladder.
For SI: 1 degree = 0.017 rad, 1 inch = 25.4 mm, 1 foot = 304.8 mm
CHART 1
"C" DIMENSION
"W" DIMENSION
14'-6"
14'-6"
16'-6"
18'-6"
21'-0"
= AB + BC
= WIDTH AT PT.C
5'-0"
6'-0"
6'-0"
7'-6"
7'-6"
Figure 20
18
Figure 19