Commissioning; Keypad And Display Layout - Siemens SITRANS F C MASSFLO MASS 2100 Operating Manual

Mass series flowmeters signal converter and sensor
Hide thumbs Also See for SITRANS F C MASSFLO MASS 2100:
Table of Contents

Advertisement

    
SITRANS F C MASSFLO
5.

Commissioning

5.1 Keypad and display
layout
Keypad
Display
16
5. Commissioning
The keypad is used to set the flowmeter. The function of the keys are as follows:
TOP UP KEY
FORWARD KEY
BACKWARD KEY
CHANGE KEY
SELECT KEY
LOCK/UNLOCK KEY
The display is alphanumerical and indicates flow values, flowmeter settings and error messsages.
The upper line is for primary flow readings and will always show either mass flowrate, volume
flowrate, density, temperature, totalizer 1 or totalizer 2. The line is divided into 3 fields.
S: Sign field
P: Primary field for numerical value
U: Unit field
The centre line is the title line (T) with individual information according to the selected operator
or setup menu.
The lowest line is the subtitle line (ST) which either will add information to the title line or keep
individual information independent of the title line.
F:
The alarm field.
Two flashing triangles will appear by a fault condition.
M: The mode field. The symbols indicate the following.
Communication mode
Service mode
Operator menu
Product identity
Language mode
L:
The lock field. Indicates the function of the lock key.
Ready for change
Value locked
SFIDK.PS.028.R1.02
This key (hold 2 sec.) is used to switch between operator
menu and setup menu. In the converter setup menu, a short
press will cause a return to the previous menu.
This key is used to step forward through the menus. It is the
only key normally used by the operator.
This key is used to step backward through the menus.
This key changes the settings or numerical values.
This key selects the figures to be changed.
This key allows the operator to change settings and gives
access to submenus.
Basic settings
Output
External input
Sensor characteristic
Reset mode
Access to submenu (Press
RESET MODE: Zero setting of
totalizers and initialization of setting
)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans f c massflo mass 6000

Table of Contents