Signal Converter Mass 6000 - Siemens SITRANS F C MASSFLO MASS 2100 Operating Manual

Mass series flowmeters signal converter and sensor
Hide thumbs Also See for SITRANS F C MASSFLO MASS 2100:
Table of Contents

Advertisement

    
SITRANS F C MASSFLO

4.2 Signal converter MASS 6000

Measurement of
Current output
Current
Load
Time constant
Digital output
Frequency
Time constant
Active
Passive
Relay
Type
Load
Functions
Digital input
Functionality
Galvanic isolation
Cut-off
Low-flow
Limit function
Totalizer
Display
Zero-point adjustment
Ambient temperature
Communication
Enclosure 19"
Material
Rating
Mecanical load
Supply voltage
Power consumption
EMC performance
Emission
Immunity
Ex-approval
Maintenance
Fuse
Cable
Intrinsically safe
interface
14
4. Technical data
MASS 6000 19" IP 20/IP 65 version
Mass flow [kg/s], volume flow [l/s], fraction [%], Brix, density [kg/m
0-20 mA or 4-20 mA
< 800 ohm
0-30 s adjustable
0-10 kHz, 50% duty cycle
0-30 s adjustable
24 V d.c., 30 mA, 1 KΩ ≤ R
load
3-30 V d.c., max. 110 mA, 1 KΩ ≤ R
Change-over relay
42 V / 2 A peak
Error level, error number, limit, direction
11-30 V d.c.
Start/hold/continue batch, zero-point adjust, reset totalizer 1/2, force output, freeze output
All inputs and outputs are galvanically isolated, isolation voltage 500 volts
0-9.9% of maximum flow
Mass flow, volume flow, fraction, density, sensor temperature
Two eight-digit counters for forward, net or reverse flow
Background illumination with alphanumerical text, 3 × 20 characters to indicate flow rate, totalized
values, settings and faults.
Reverse flow indicated by negative sign
Manual via keypad or remote via digital input
°C
Operation: −20
to +50°C
°C
During storage: −40
to +70°C (Humidity max. 95%)
Prepared for client mounted add-on modules
Aluminium/steel (DIN 41494)
IP 20 to IEC 529 and DIN 40050 (1 m w.g. for 30 min.)
18-1000 Hz random, 3.17G rms, in all directions, to IEC 68-2-36
115/230 V a.c. +10% to −10%, 50-60 Hz
18-30 V d.c. or 20-30 V a.c.
230 V a.c.: 9 VA max.
24 V d.c.: 6 W I
= 250 mA, I
N
ST
EN 50081-1 (Light industry)
EN 50082-2 (Industry)
[EEx ia] II C, DEMKO 03 ATEX 135251X
The flowmeter has a built-in error log/pending menu which should be inspected on a regular basis
T 400 mA, T 250 V (IEC 127). Not replaceable by operator
Max. 300 m with cable code no. FDK:083H3005 or FDK:083H3006
C: max. 300 [pF/m]; L
/R
: max. 100 [µH/Ω]
c
c
The total cable capacity have to be max. 200 nF
Terminals
81-82
U
[V]
16
o
I
[mA]
122
o
P
[W]
0.55
o
L
or
[mH]
2 or
o
L
/R
[µH/Ω]
100
o
o
C
[nF]
200
o
SFIDK.PS.028.R1.02
≤ 10 KΩ, short-circuit-protected
≤ 10 KΩ
load
= 2A (30 msec)
83-84 & 89-90
15
8
0.03
10
200
3
], temperature [°C]
85-86 & 87-88
15
15
0.056
10
200

Advertisement

Table of Contents
loading