Chapter9 Appendix
(1)Open the 18firon.cfg file by text editor (Example: Notepad), and change it.
Change part is IP Address which is adding shading, and please input the IP address of Server
PC.
In this example, since it is "Server PC=192.168.0.10", it is set to source="192.168.0.10."
# Command Handler configuration
# System configuration
set system name="VDR_IF"
# User configuration
set user=manager pass=3af00c6cad11f7ab5db4467b66ce503eff priv=manager lo=yes
set user=manager telnet=yes desc="Manager Account"
# IP configuration
Change to192.168.0.10
enable ip
add ip interface=vlan1 ip=192.168.0.100 mask=255.255.255.0
add ip interface=eth0 ip=192.168.111.100 mask=255.255.255.0
# INT configuration
add ip filter=0 type=traffic source=192.168.0.251 ac=include smask=255.255.255.255 destination=192.168.111.152
dmask=255.255.255.255 icmptype=8 prot=icmp
add ip filter=0 type=traffic source=192.168.0.251 ac=include smask=255.255.255.255 destination=192.168.111.152
dmask=255.255.255.255 dport=80 prot=tcp
add ip filter=0 type=traffic source=192.168.0.251 ac=include smask=255.255.255.255 destination=192.168.0.100
dmask=255.255.255.255 dport=23 prot=tcp
set ip int=vlan1 filter=0