Table 10. INIT Command Generated Defaults
Parameter
For all radios
Device operation
RF output power
CTS delay
CTS hold-time
DATA Interface port
Alarm Mask

Alarm Output Sense

RX Time-out-Timer
Transmitter
test frequency
Receiver
test frequency
Sleep Enable
Data Port Setting
Primary Extension
Radio Address
Synchronization
Source Map
Extended Address
For MASTER radios
Skipped frequencies
Hop-time
Buffer mode
Retry Count
Repeat Count
Forward Error
Correction
MDS 05-2708A01, Rev. B
Default Setting
DCE
30 dBm (1 watt)
0
(CTS is continuously asserted)
0
• 9600 baud
• 8 data bits
• none (no parity)
• 1 stop bit
FFFF FFFF
RS-232 High (+5.0 Vdc)
None/Disable
915.000 MHz
915.000 MHz
OFF
RS/EIA-232
0 (Master)
None
0
None (radio will hop across all
frequencies)
7 ms
OFF
10 (max. 10 repeats for ARQ)
3 (downstream repeats)
ON
MDS TransNET 900 I&O Guide
Corresponding
Command
DEVICE DCE
PWR 30
CTS 0
CTSHOLD 0
BAUD 9600 8N1
AMASK
ASENSE
RXTOT
TX xxx
RX xxx
SLEEP OFF
PORT RS232
XPRI 0
XMAP 0
XADDR 0
SKIP NONE
HOPTIME 7
BUFF OFF
RETRY 10
REPEAT 3
FEC ON