EMS Marker Location
RD400PDL-2/PXL-2 User Guide

Buried Conductor and Marker Locate

The receiver can now be used to locate a buried
conductor and a Marker simultaneously. The
Left/Right arrows [7] indicate the buried conductor
position while the bargraph [8] and numeric
display indicate the amplitude of the received
Marker signal.
The EMS Marker Locate Mode has two gain levels
(Hi and Lo) indicated at top left of the display [9].
These levels are selected using either the
Up/Down keys [10] (Up for Hi, Down for Lo) or the
Rotary Gain Control (clockwise for Hi,
anticlockwise for Lo). The buried conductor signal
gain is controlled automatically in this mode.
When a marker is located a variable audio tone is
sounded.

Marker Locate Only

To select the EMS Marker Locate Mode only with
no Buried Conductor Locate Mode press the 'Hot
Key' [13]. This will allow the marker to be
pinpointed. Marker Type Code selection and Gain
control are as previously described.
Connection of Other Accessories with EMS
Boot Fitted
Connecting another accessory when the EMS
Boot is fitted switches the EMS Marker Locate
Mode flag off. This indicates that the EMS Marker
Locate Mode is disabled and the other accessory
has priority.
When the EMS Boot is fitted certain features are
disabled:
Depth mode.
CD and Current measurement modes.
Line/Sonde key.