Depth in Power Mode

As current on power cables may fluctuate Depth
readings in Power mode are NOT as reliable as
active transmitter Depth measurements.
Current
Active signal current can be measured in the same
active locating modes available with the Depth
feature.
Pinpoint the target line as previously described.
Press the Current key once. Current reading is
displayed for a few seconds.
CD (RD400PDL-2 only)
Set Transmitter to provide a CD signal.
Using Frequency/Mode key select CD mode, hold
Receiver over target line close to, and with back
to, Transmitter.
CD - Reset (RD400PDL-2 only)
Before using Current Direction information a CD
reset must be carried out. (Refer to the
appropriate Receiver section).
When reset, Receiver will indicate target line
current direction flowing away from Transmitter.