Installation Instructions; Precaution - Easson ES-12 Operation Manuals

Digital readout system
Table of Contents

Advertisement

A. Precaution:
1. The travel length of the glass grating scale must be longer than the maximum travel of the machine,
there should be at least 10mm clearance between the ends of the glass scale and the maximum travel
of the machine as per the following figure shown.
2
. To ensure the graduated glass scale to be installed is reliable, and to avoid any possibility of scale
misalignment, the scale should be installed on machined flat surfaces of the machine wherever possible.
In the case where there are no machined flat surfaces available on the machine, machined flat Blocks
or the stainless steel fillers should be used. Wherever possible the scale ends and the reader head
should be installed on a flat surface.
3
. If a lever dial indicator is used to align the scale, it is important to ensure that the angle between the
dial Indicator lever tip and the surface measured must be less than 30'to avoid a cosine measurement
Error. If a vertical dial indicator is used as per the following figures shown, it is important to ensure
that the dial indicator is perpendicular to the measured surface to also avoid the cosine measurement
error.
Easson
Always Committed to Quality Technology & Innovation

Installation Instructions

A
C
¡]Clearance>10mm¡^
- C. 1 -
B
D