Parameters Setup Procedure - FLTR. PR & QUIT
FLTR. PR. menu is designed to allow user to specifies the filtering range of vibration for the vibration filtering
function.
This version of software is offering vibration filtering as one of the standard function in the ES-12.
This function is used prmary for big or very old machine which the machine structure is not ver y rigid to
resist the vibration when during machining or axis movement.
The bigger the FLTR. PR, the bigger the filtering effect. Slower movement will be observed.
Please notice that the vibration filter won't affect the accuracy of the counting. The measurement accuracy
is the same with or without the filter.
Press
to select the "FLTR. PR" selection menu
X
Y
Z
U
FLTR. PR
specify the FLTR. PR
X
30
Y
Z
U
FLTR. PR
Press
to select the "QUIT" selection menu
X
Y
Z
U
QUIT.
For example, we change
the FLTR. PR to 60 for
higher filtering effect
6
0
X
Y
Z
U
DRO displays "FLTR PR." means
DRO have entered into the
FLTR. PR selection menu, user
must specify the vibration
filtering range to the DRO.
X
Y
60
Z
U
FLTR. PR
Please notice that the DRO must be switched
off after quit from the SETUP function, otherwise,
some of the new parameters may not be able
to take effect
- B. 23 -
30
FLTR. PR
selection done,
go to next menu